ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

脈絡膜悪性黒色腫における回転ガントリーの有用性に関する研究

https://repo.qst.go.jp/records/66808
https://repo.qst.go.jp/records/66808
792a3c3e-f0fe-49b5-92d9-a1445060377f
Item type 会議発表用資料 / Presentation(1)
公開日 2018-05-11
タイトル
タイトル 脈絡膜悪性黒色腫における回転ガントリーの有用性に関する研究
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 牧島, 弘和

× 牧島, 弘和

WEKO 656888

牧島, 弘和

Search repository
辻, 比呂志

× 辻, 比呂志

WEKO 656889

辻, 比呂志

Search repository
粕谷, 吾朗

× 粕谷, 吾朗

WEKO 656890

粕谷, 吾朗

Search repository
早乙女, 直也

× 早乙女, 直也

WEKO 656891

早乙女, 直也

Search repository
坂間, 誠

× 坂間, 誠

WEKO 656892

坂間, 誠

Search repository
米内, 俊介

× 米内, 俊介

WEKO 656893

米内, 俊介

Search repository
兼松, 伸幸

× 兼松, 伸幸

WEKO 656894

兼松, 伸幸

Search repository
鎌田, 正

× 鎌田, 正

WEKO 656895

鎌田, 正

Search repository
牧島 弘和

× 牧島 弘和

WEKO 656896

en 牧島 弘和

Search repository
辻 比呂志

× 辻 比呂志

WEKO 656897

en 辻 比呂志

Search repository
粕谷 吾朗

× 粕谷 吾朗

WEKO 656898

en 粕谷 吾朗

Search repository
早乙女 直也

× 早乙女 直也

WEKO 656899

en 早乙女 直也

Search repository
坂間 誠

× 坂間 誠

WEKO 656900

en 坂間 誠

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 656901

en 兼松 伸幸

Search repository
鎌田 正

× 鎌田 正

WEKO 656902

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract
Purpose
To evaluate the advantage of use of rotating gantry and energy scanning carbon-ion beams for choroidal malignant melanoma and prepare for clinical use.
Materials and Methods
Dose distribution were evaluated by dose-volume histograms and 3D dose distribution.
Quality assurance and control (QA / QC) methods were also evaluated. Linear energy transfer (LET) of energy scanning, accuracy of spot depth, position, and dose were evaluated using an in-house built jig.
Imobilization devices, position confirmation and beam control systems were also checked for treatment.
Results
Evaluation of dose distribution showed improvement in doses to risk tissues compared to passive scattering beams, but with higher maximum dose. The higher maximum dose was evaluated clinically insignificant.
Lower LET was observed in energy scanning. Dose converting for lower energies were offset by XX%. Spot position accuracy was obtained by using rescanning techniques.
Imobilization devices were confirmed to fit in the new treatment room. Position confirmation was possible using a head phantom. Patient monitoring and beam control systems functioned properly with minor modifications.
Conclusion
Energy scanning with the rotating gantry showed to be equal to superior compared to passive scattering. We have successfully constructed a workflow for QA / QC and is ready for clinical application.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 H29年度HIMAC共同利用研究成果発表会
発表年月日
日付 2018-04-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:44:40.779098
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3