WEKO3
アイテム
SDDR analysis in equatorial port interspace with WCCB TBM-set
https://repo.qst.go.jp/records/66757
https://repo.qst.go.jp/records/667579bc77861-2469-4901-90ba-5554e4657ea1
| Item type | 会議発表用資料 / Presentation(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2018-03-30 | |||||
| タイトル | ||||||
| タイトル | SDDR analysis in equatorial port interspace with WCCB TBM-set | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
| 資源タイプ | conference object | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
権, 暁星
× 権, 暁星× 谷川, 尚× 廣瀬, 貴規× 河村, 繕範× 飯田, 浩正× 権 暁星× 谷川 尚× 廣瀬 貴規× 河村 繕範 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Target of SDDR in the port interspace is below 100 μSv/hr to permit personnel access for maintenance. The SDDR in the port interspace with WCCB TBM set was evaluated with MCNP5_D1S, and it was over 100 μSv/hr at 10^6 sec after shutdown. Counter measure of too high SDDR was proposed in present study. The SDDR could be decreased below 100 μSv/hr by using shims and B4C tiles. | |||||
| 会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | 12th ITER Neutronics Meeting | |||||
| 発表年月日 | ||||||
| 日付 | 2017-10-12 | |||||
| 日付タイプ | Issued | |||||