Treatment planning of intensity modulated composite particle therapy with dose and linear energy transfer optimization

https://repo.qst.go.jp/records/66445
https://repo.qst.go.jp/records/66445
e6caaac2-eec0-4cb6-aebb-1391374dd9f6
Item type 会議発表用資料 / Presentation(1)
公開日 2017-09-21
タイトル
タイトル Treatment planning of intensity modulated composite particle therapy with dose and linear energy transfer optimization
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 稲庭, 拓

× 稲庭, 拓

WEKO 653704

稲庭, 拓

Search repository
兼松, 伸幸

× 兼松, 伸幸

WEKO 653705

兼松, 伸幸

Search repository
野田, 耕司

× 野田, 耕司

WEKO 653706

野田, 耕司

Search repository
鎌田, 正

× 鎌田, 正

WEKO 653707

鎌田, 正

Search repository
稲庭 拓

× 稲庭 拓

WEKO 653708

en 稲庭 拓

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 653709

en 兼松 伸幸

Search repository
野田 耕司

× 野田 耕司

WEKO 653710

en 野田 耕司

Search repository
鎌田 正

× 鎌田 正

WEKO 653711

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 The biological effect of charged-particle beams depends on radiation quality represented practically by the linear energy transfer (LET). Thus, the dose and the LET should be optimized for ideal charged-particle therapy. We investigated a new therapeutic technique using two or more ion species in one treatment session, which we call an Intensity Modulated composite PArtiCle Therapy (IMPACT), for optimizing the dose and LET distributions in a patient. Protons and helium, carbon, and oxygen ions were considered as ion species for IMPACT. For three cubic targets of 4 × 4 × 4, 8 × 8 × 8, and 12 × 12 × 12 cm3 defined at the center of the water phantom of 20 × 20 × 20 cm3, we made IMPACT plans of two fields with opposing and orthogonal geometries. The prescribed dose to the target was fixed at 1 Gy, while the prescribed LET to the target was varied from 1 keV/μm to 120 keV/μm to investigate the adjustable range of LET. The minimum and maximum prescribed LETs, (LT_min, LT_max), by the opposing-field geometry were (3 keV/μm, 115 keV/μm), (2 keV/μm, 84 keV/μm), and (2 keV/μm, 66 keV/μm), while those by the orthogonal-field geometry were (8 keV/μm, 98 keV/μm), (7 keV/μm, 72 keV/μm), and (8 keV/μm, 57 keV/μm) for the three targets, respectively. To show the availability of the technique in a clinical situation, we made IMPACT plans for a prostate case. In accordance with the prescriptions, LETs in prostate, planning target volume (PTV), and rectum could be adjusted at 80 keV/μm, at 50 keV/μm, and below 30 keV/μm, respectively, while keeping the dose to the PTV at 2 Gy uniformly. IMPACT enables the optimization of the dose and the LET distributions in a patient, which will maximize the potential of charged particle therapy by expanding the therapeutic window.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第114回日本医学物理学会学術大会
発表年月日
日付 2017-09-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:48:52.355181
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3