WEKO3
アイテム
Radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors
https://repo.qst.go.jp/records/66395
https://repo.qst.go.jp/records/663950e980ed8-05f0-4df3-a37b-3fe0692bd93b
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-09-04 | |||||
タイトル | ||||||
タイトル | Radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× 小平 聡 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recently, 211At has received increasing attention as a potential radionuclide for cancer radioimmunotherapy. It is α-particle emitter, which is extremely effective against malignant cells. We demonstrate a method to verify the efficiency of 211At-labeled trastuzumab antibodies (211At-trastuzumab) against HER2 antigens, which has not been determined for radioimmunotherapy. A CR-39 plastic nuclear detector is used for measuring the position and the linear energy transfer (LET) of individual 211At α- particle tracks. The tracks and 211At-trastuzumab-binding cells were co-visualized by using the geometric information recorded on the CR-39. HER2-positive human gastric cancer cells (NCI-N87), labelled with 211At-trastuzumab, were dropped on the centre of the CR-39 plate. Microscope images of the cells and the corresponding α-tracks acquired by position matching were obtained. The distribution of number of α-particles emitted from single cells suggests that 80% of the 211At-trastuzumab-binding cells emitted α-particles. It also indicates that the α-particles may strike the cells several times along their path. The track-averaged LET of the α-particles is evaluated to be 131 keV/µm. These results will enable quantitative evaluation of delivered doses to target cells, and will be useful for the in vitro assessment of 211At-based radioimmunotherapeutic agents.We will present the current status of radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for the in vitro assessment of 211At-based radioimmunotherapeutic agents. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 27th International Conference on Nuclear Tracks and Radiation Measurements | |||||
発表年月日 | ||||||
日付 | 2017-08-29 | |||||
日付タイプ | Issued |