ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors

https://repo.qst.go.jp/records/66395
https://repo.qst.go.jp/records/66395
0e980ed8-05f0-4df3-a37b-3fe0692bd93b
Item type 会議発表用資料 / Presentation(1)
公開日 2017-09-04
タイトル
タイトル Radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 653310

Kodaira, Satoshi

Search repository
小平 聡

× 小平 聡

WEKO 653311

en 小平 聡

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, 211At has received increasing attention as a potential radionuclide for cancer radioimmunotherapy. It is α-particle emitter, which is extremely effective against malignant cells. We demonstrate a method to verify the efficiency of 211At-labeled trastuzumab antibodies (211At-trastuzumab) against HER2 antigens, which has not been determined for radioimmunotherapy. A CR-39 plastic nuclear detector is used for measuring the position and the linear energy transfer (LET) of individual 211At α- particle tracks. The tracks and 211At-trastuzumab-binding cells were co-visualized by using the geometric information recorded on the CR-39. HER2-positive human gastric cancer cells (NCI-N87), labelled with 211At-trastuzumab, were dropped on the centre of the CR-39 plate. Microscope images of the cells and the corresponding α-tracks acquired by position matching were obtained. The distribution of number of α-particles emitted from single cells suggests that 80% of the 211At-trastuzumab-binding cells emitted α-particles. It also indicates that the α-particles may strike the cells several times along their path. The track-averaged LET of the α-particles is evaluated to be 131 keV/µm. These results will enable quantitative evaluation of delivered doses to target cells, and will be useful for the in vitro assessment of 211At-based radioimmunotherapeutic agents.We will present the current status of radiation dosimetry of α-particle emission from 211At-labeled antibodies in single cells for the in vitro assessment of 211At-based radioimmunotherapeutic agents.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 27th International Conference on Nuclear Tracks and Radiation Measurements
発表年月日
日付 2017-08-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:49:26.475576
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3