External dose audits of high-energy radiotherapy photon beams in Japan

https://repo.qst.go.jp/records/66217
https://repo.qst.go.jp/records/66217
af255fb6-73ba-472a-a205-471a0e39f53d
Item type 会議発表用資料 / Presentation(1)
公開日 2017-03-22
タイトル
タイトル External dose audits of high-energy radiotherapy photon beams in Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 佐方, 周防

× 佐方, 周防

WEKO 651628

佐方, 周防

Search repository
Yamasita, Wataru

× Yamasita, Wataru

WEKO 651629

Yamasita, Wataru

Search repository
Takase, Nobuhiro

× Takase, Nobuhiro

WEKO 651630

Takase, Nobuhiro

Search repository
Hoteida, Masahiro

× Hoteida, Masahiro

WEKO 651631

Hoteida, Masahiro

Search repository
Sasaki, Yousuke

× Sasaki, Yousuke

WEKO 651632

Sasaki, Yousuke

Search repository
Okumura, Hiroaki

× Okumura, Hiroaki

WEKO 651633

Okumura, Hiroaki

Search repository
Usiroda, Tota

× Usiroda, Tota

WEKO 651634

Usiroda, Tota

Search repository
水野, 秀之

× 水野, 秀之

WEKO 651635

水野, 秀之

Search repository
福村, 明史

× 福村, 明史

WEKO 651636

福村, 明史

Search repository
Narita, Katsuhisa

× Narita, Katsuhisa

WEKO 651637

Narita, Katsuhisa

Search repository
佐方 周防

× 佐方 周防

WEKO 651638

en 佐方 周防

Search repository
水野 秀之

× 水野 秀之

WEKO 651639

en 水野 秀之

Search repository
福村 明史

× 福村 明史

WEKO 651640

en 福村 明史

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Nine years have passed since the Association for Nuclear Technology in Medicine (ANTM) launched the external dose quality audit (EDQA) of high energy radiotherapy photon beams for radiotherapy departments in Japan. When EDQA was started, the object was limited to beams of reference condition (10cm square field size, 10cm depth in water) and was expanded to non-reference conditions of field size changes and wedge filter insertions in 2010. In this study we report the results of this EDQA and the present status of dose estimation in Japan evaluated from EDQA.
Methods: In the EDQA by ANTM, radiophotoluminescent glass dosimeter (RGD) is used as the detector. ANTM send RGD elements and solid phantom to radiotherapy departments and RGD are returned to ANTM after the irradiation of a specified dose. The dose delivered to RGD is measured at Dose Calibration Center of ANTM and is compared to the dose stated by radiotherapy department.
Results: Until March 2016, 3,351 beams of 784 therapy units from 629 departments have been audited. The numbers of beams are classified into 1,663 of reference condition, 1,103 of field size change and 585 wedge filter insertion. The averages of difference between measured and stated dose were 0.39% in reference condition, 0.19% in field changes and 0.17% in wedge filter insertions. The standard deviations were around 1% for all conditions.
Conclusions: The external dose QA by ANTM shows that the status of dosimetry at radiotherapy departments in Japan is in satisfying level.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Congress of Medical Physics, 2016
発表年月日
日付 2016-12-08
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:51:27.322081
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3