ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Radiophotoluminescent glass dosimeter application to the dose audit of flattening-filter-free linear accelerator, Tomotherapy and Cyberknife

https://repo.qst.go.jp/records/66043
https://repo.qst.go.jp/records/66043
b3d2a00c-9e0c-4e7e-bf7d-afa48ab2cb96
Item type 会議発表用資料 / Presentation(1)
公開日 2016-12-15
タイトル
タイトル Radiophotoluminescent glass dosimeter application to the dose audit of flattening-filter-free linear accelerator, Tomotherapy and Cyberknife
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 水野, 秀之

× 水野, 秀之

WEKO 650304

水野, 秀之

Search repository
遠山, 尚紀

× 遠山, 尚紀

WEKO 650305

遠山, 尚紀

Search repository
福村, 明史

× 福村, 明史

WEKO 650306

福村, 明史

Search repository
福田, 茂一

× 福田, 茂一

WEKO 650307

福田, 茂一

Search repository
佐方, 周防

× 佐方, 周防

WEKO 650308

佐方, 周防

Search repository
山下, 航

× 山下, 航

WEKO 650309

山下, 航

Search repository
高瀬, 信宏

× 高瀬, 信宏

WEKO 650310

高瀬, 信宏

Search repository
水野 秀之

× 水野 秀之

WEKO 650311

en 水野 秀之

Search repository
遠山 尚紀

× 遠山 尚紀

WEKO 650312

en 遠山 尚紀

Search repository
福村 明史

× 福村 明史

WEKO 650313

en 福村 明史

Search repository
福田 茂一

× 福田 茂一

WEKO 650314

en 福田 茂一

Search repository
佐方 周防

× 佐方 周防

WEKO 650315

en 佐方 周防

Search repository
山下 航

× 山下 航

WEKO 650316

en 山下 航

Search repository
高瀬 信宏

× 高瀬 信宏

WEKO 650317

en 高瀬 信宏

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: In Japan, postal dose audits have been performed on radiation therapy units using a radiophotoluminescent glass dosimeter (RGD), since 2007. The purpose of this study was to obtain a set of correction factors of the RGD output for reference condition for flattening-filter-free linear accelerator (FFF), Tomotherapy (Tomo) and Cyberknife (CK).
Methods: Special phantom was designed in order to place 3 RGD elements in a tiny uniform region (dose gradient < 0.2%) at a field center around 3 mm. RGDs were irradiated by using this phantom for 1 Gy. Ionization chamber measurements using an A1SL chamber (Exradin) were done for same reference condition and monitor units for each modality. The response of RGD were evaluated by calculating the ratio between RGD and IC outputs. For every modality, at least 3 different machines were used and the results were averaged to derive final response of the RGD.
Results: The response of the RGD was -0.1% (6 MV) and -0.6% (10 MV) for FFF, -0.8% (6 MV) for Tomo, and -0.1% (6 MV) for CK. The RGD showed good responses of less than 1% for the beam from every modality. For FFF beam, the difference could be attributed to the decrease of kQ for IC measurement of FFF beam that was mentioned in some published papers.
Conclusion: RGD was proved to be useful to the modern treatment units. We will expand our audit application to such new modalities.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Medical Physics 2016
発表年月日
日付 2016-12-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:53:23.291696
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3