ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Recent progress and future plan of heavy-ion cancer radiotherapy with HIMAC

https://repo.qst.go.jp/records/65925
https://repo.qst.go.jp/records/65925
7b63b19a-6f1d-4016-9ca1-453ba9dc65fc
Item type 会議発表用資料 / Presentation(1)
公開日 2016-07-19
タイトル
タイトル Recent progress and future plan of heavy-ion cancer radiotherapy with HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Noda, Koji

× Noda, Koji

WEKO 649394

Noda, Koji

Search repository
野田 耕司

× 野田 耕司

WEKO 649395

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 The HIMAC clinical study has been conducted with a carbon-ion beam since June 1994. The total number of patients treated was around 10,000 as of March 2016. As a new treatment research project [1], NIRS has developed both the accelerator and beam-delivery technologies for the sophisticated heavy-ion radiotherapy since 2006, which brings both the static and moving-tumour radiotherapy technologies by the fast 3D scanning. The fast 3D scanning with a pencil beam, which is called NIRS-scanning, has been carried out for the static-tumour treatment since May 2011, while the moving-tumour treatment since March 2015. In the NIRS-scanning, further, the variable-energy operation from 430 to 56 MeV/u by the HIMAC synchrotron itself, instead of energy-degraders, has been performed for the depth scanning since September 2015. At the present, a heavy-ion rotating gantry has been successfully developed with the superconducting technology and is in a beam-commissioning stage. As a future plan, we just start a study of the LETpainting with a carbon-ion beam, which will be realize combining the NIRS-scanning and the rotating gantry. The multi-ions operation will bring more sophisticated LETpainting, which will be realized by a time-sharing operation of the HIMAC accelerator complex. Further, we just start the design study for a superconducting synchrotron with a diameter less than 10 m for more compact heavy-ion radiotherapy machine. The recent progress and the future plan of the heavy-ion cancer radiotherapy with HIMAC is
reported.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 12th European Conference on Accelerators in Applied Research and Technology (ECAART12)
発表年月日
日付 2016-07-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:54:45.973922
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3