ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Patient Data-Based Monte Carlo Simulation of in-Beam Single-Ring OpenPET Imaging

https://repo.qst.go.jp/records/65815
https://repo.qst.go.jp/records/65815
68f07a24-cf72-440f-b325-011d0c6bdb9f
Item type 会議発表用資料 / Presentation(1)
公開日 2015-11-20
タイトル
タイトル Patient Data-Based Monte Carlo Simulation of in-Beam Single-Ring OpenPET Imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 田島, 英朗

× 田島, 英朗

WEKO 776362

田島, 英朗

Search repository
Kurz, C.

× Kurz, C.

WEKO 776363

Kurz, C.

Search repository
吉田, 英治

× 吉田, 英治

WEKO 776364

吉田, 英治

Search repository
Debus, j.

× Debus, j.

WEKO 776365

Debus, j.

Search repository
Parodi, K.

× Parodi, K.

WEKO 776366

Parodi, K.

Search repository
山谷, 泰賀

× 山谷, 泰賀

WEKO 776367

山谷, 泰賀

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 776368

en Tashima, Hideaki

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 776369

en Yoshida, Eiji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 776370

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing the OpenPET, which can provide an open space to make the patient accessible during positron emission tomography (PET) measurements. The OpenPET provides PET measurements during particle therapy such as carbon ion beam treatment, enabling visualization of the irradiation field of the patient as well as direct tumor tracking with a real-time imaging system. In the carbon ion beam treatment, positron emitters are produced by the fragmentation reactions. Therefore, by means of PET, it can be confirmed whether or not the dose distribution in the treatment plan and that in the actual irradiation are matched. In this study, we conducted Monte Carlo simulations based on clinical patient data for scanned 12C ion beam irradiation to investigate the effectiveness of the OpenPET geometry compared with offline PET measurements. Production rates of the positron emitters were calculated based on the patient CT image and physical dose information in the treatment plan by the FLUKA code. The activity distribution averaged over the measurement time was calculated from the production rates by an analytical model including activity decay and biological washout effects. Annihilation gamma ray events from the activity distribution were simulated by the Geant4 Monte Carlo toolkit. Activity distribution images were reconstructed by the list-mode maximum a posteriori ordered subset expectation maximization. As a result, we found the online OpenPET with a measurement time of 10 minutes could detect a similar number of list-mode data events as an offline PET with a measurement time of 30 minutes. Reconstructed images for the online OpenPET contained activity distribution not only around the distal edge but also at the entrance area of the irradiation field. The offline PET showed strong noise before the Bragg peak position. The simulation results showed that online OpenPET could achieve good quality of images with a short measurement time.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2015 IEEE NSS&MIC
発表年月日
日付 2015-11-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:47:08.042218
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3