ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Recent Development of Heavy-Ion Radiotherapy Technology with HIMAC

https://repo.qst.go.jp/records/65809
https://repo.qst.go.jp/records/65809
7264aff7-ad8d-4f78-9dda-29673343b10d
Item type 会議発表用資料 / Presentation(1)
公開日 2015-11-18
タイトル
タイトル Recent Development of Heavy-Ion Radiotherapy Technology with HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Noda, Koji

× Noda, Koji

WEKO 648250

Noda, Koji

Search repository
野田 耕司

× 野田 耕司

WEKO 648251

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since 1994, Heavy-Ion Medical Accelerator in Chiba, HIMAC, has treated patients of more than 9,000 with the carbon-ion radiotherapy. Recently, NIRS has been engaged in a “new treatment research project” toward the further development of the HIMAC treatment. In this project, the phase-controlled rescanning (PCR), based on a fast 3D scanning, has been developed toward “adaptive cancer radiotherapy” of both the static and moving tumors. This fast 3D scanning employs the depth scanning with multiple energy beams delivered during one operation cycle of the synchrotron, while the lateral scanning with 100 times speed-up compared with the conventional spot scanning. The new treatment research facility was constructed with HIMAC for the clinical study with this technology, which has been successfully conducted since 2011. As the next stage, a compact carbon-ion rotating gantry with the superconducting technology has been developed in order to realize the intensity modulated carbon-ion radiotherapy combined with the 3D scanning, which will bring the more accurate and shorter-course treatments owing to the higher dose concentration. This rotating gantry was already installed and its commissioning will be started within 2015. Recent development of the heavy-ion radiotherapy with HIMAC will be reported.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 12th International topical meeting on nuclear application of accelerators (AccApp”15)
発表年月日
日付 2015-11-10
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:56:01.198470
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3