Evaluation of the depth dose distribution using a graphite calorimeter and ionization chambers in 290 MeV/n carbon ion beam

https://repo.qst.go.jp/records/65664
https://repo.qst.go.jp/records/65664
3ff861e3-9c6d-497b-9766-5021e7b559c1
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-01
タイトル
タイトル Evaluation of the depth dose distribution using a graphite calorimeter and ionization chambers in 290 MeV/n carbon ion beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 坂間, 誠

× 坂間, 誠

WEKO 646813

坂間, 誠

Search repository
坂間 誠

× 坂間 誠

WEKO 646814

en 坂間 誠

Search repository
抄録
内容記述タイプ Abstract
内容記述 In radiotherapy, the ionization chambers are usually used in the dosimetry and this method needs the beam quality correction factors to obtain the absorbed dose to water for used beam quality. These factors are composed of the stopping power ratios, the w values and the perturbation factors for the ionization chamber. The factors for the heavy-ion beams have large uncertainties and are assumed to be constant values for all conditions in the IAEA TRS 398 protocol. In this study, the depth dose distributions of carbon ion beam were measured by the developed graphite calorimeter and also by ionization chambers following the IAEA protocol. Comparisons of absorbed dose to graphite obtained by the graphite calorimeter and the ionization chambers are discussed in order to evaluate the depth dependence of the beam quality correction factors in the therapeutic carbon ion beam. In 290 MeV/n carbon ion beam, a cylindrical chamber (PTW type 30011, Farmer) and a plane-parallel chamber (PTW Advanced Markus) calibrated by the secondary standard dosimetry laboratory were used. The beam quality correction factors were obtained by the comparisons and the beam quality information from Monte Carlo simulation. The depth dose distributions in graphite obtained by the ionization chambers were agreed well without the Bragg peak region. The differences of the distributions obtained by the chambers and calorimeter changed slightly with the depth. The relative doses of the chambers were overestimated comparing with that of calorimeter. Therefore, the relative beam quality correction factors will become smaller increasing the depth before the Bragg peak. Relative dose measurements were performed using the calorimetry and ionization chamber dosimetry in the carbon ion beam. The calorimetry in Bragg peak region will be complicated due to the steep dose gradient, the influence of fragment particles and other correction factors. The difference of relative dose distributions between ionization chambers and the calorimeter is larger increasing the depth. The change of relative beam quality correction factors will be influenced by the w value in air in the heavy ions. More detailed information about depth dependence of the beam quality correction factors will be needed to sophisticate the dosimetry of carbon ion beam.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 15th International Congress of Radiation Research (ICRR 2015)
発表年月日
日付 2015-05-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:57:38.127392
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3