ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Delivered 4D Dose Calculation for Lung-VMAT Patients Using In-Treatment CBCT and LINAC Log Data

https://repo.qst.go.jp/records/65485
https://repo.qst.go.jp/records/65485
24c1f1a8-5442-44b2-97cb-a7ff2561e56b
Item type 会議発表用資料 / Presentation(1)
公開日 2014-08-25
タイトル
タイトル Delivered 4D Dose Calculation for Lung-VMAT Patients Using In-Treatment CBCT and LINAC Log Data
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 早乙女, 直也

× 早乙女, 直也

WEKO 644993

早乙女, 直也

Search repository
Haga, A.

× Haga, A.

WEKO 644994

Haga, A.

Search repository
Imae, T.

× Imae, T.

WEKO 644995

Imae, T.

Search repository
Kida, S.

× Kida, S.

WEKO 644996

Kida, S.

Search repository
Nakano, M.

× Nakano, M.

WEKO 644997

Nakano, M.

Search repository
Yamashita, H.

× Yamashita, H.

WEKO 644998

Yamashita, H.

Search repository
Nakagawa, K.

× Nakagawa, K.

WEKO 644999

Nakagawa, K.

Search repository
Ohtomo, K.

× Ohtomo, K.

WEKO 645000

Ohtomo, K.

Search repository
早乙女 直也

× 早乙女 直也

WEKO 645001

en 早乙女 直也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
To verify the delivered four-dimensional (4D) dose distribution for the lung VMAT using in-treatment 4D cone-beam CT (CBCT) and LINAC log data. Material and methods
Three patients for lung stereotactic radiotherapy (SRT) were treated by single-arc volumetric modulated arc therapy (VMAT) created by SmartArc in Pinnacle v9.2 (Philips, USA).
Kilovoltage (kV) projection images were acquired during VMAT delivery using the x-ray volumetric imager, XVI (Elekta, UK). LINAC log data were also recorded via iCom interface (Elekta, UK). Subsequently, the iCom data format was converted to Pinnacle data format, thereby allowing Pinnacle to read actual MLC positions, jaw positions, gantry angles and MUs. These parameters were categorized into four groups according to patient’s respiratory phase. The patient respiratory phase was determined from kV-projection images by in-house phase recognizing software. By exporting these data back to Pinnacle, in-treatment dose distributions for each respiratory phase were obtained by combining calculated dose having a particular phase. The 4D CBCT were reconstructed by in-house program. The density in the structures on the CBCT was overridden by the average density in the corresponding structures on the planning CT for the dose calculation. The dose indexes, such as maximum, minimum, mean dose in the target were compared among the plan, in-treatment 3D calculation, and in-treatment 4D calculation.
Result
The day-to-day variation of the delivered dose was observed for all three patients. The maximum difference was 5.9% for the minimum dose in the target. Difference for the mean dose was found to be small (1.1% at maximum).
Conclusion
We have obtained in-treatment dose distribution for each of the different respiratory phases using in-treatment 4D CBCT and LINAC log data during
lung VMAT delivery. Our result indicate a small but significant dose difference between the 3D and 4D calculations for the case of large target traveling.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 American Association of Physicists in Medicine 56th annual meeting (AAPM2014)
発表年月日
日付 2014-07-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:59:32.250169
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3