ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Dosimetry by Means of In-Beam PET with RI Beam Irradiation

https://repo.qst.go.jp/records/65324
https://repo.qst.go.jp/records/65324
919d67f0-ad9a-40d0-b748-7fd054626062
Item type 会議発表用資料 / Presentation(1)
公開日 2013-11-15
タイトル
タイトル Dosimetry by Means of In-Beam PET with RI Beam Irradiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakajima, Yasunori

× Nakajima, Yasunori

WEKO 643744

Nakajima, Yasunori

Search repository
Hirano, Yoshiyuki

× Hirano, Yoshiyuki

WEKO 643745

Hirano, Yoshiyuki

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 643746

Tashima, Hideaki

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 643747

Yoshida, Eiji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 643748

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 643749

Satou, Shinji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 643750

Yamaya, Taiga

Search repository
et.al

× et.al

WEKO 643751

et.al

Search repository
中島 靖紀

× 中島 靖紀

WEKO 643752

en 中島 靖紀

Search repository
平野 祥之

× 平野 祥之

WEKO 643753

en 平野 祥之

Search repository
田島 英朗

× 田島 英朗

WEKO 643754

en 田島 英朗

Search repository
吉田 英治

× 吉田 英治

WEKO 643755

en 吉田 英治

Search repository
稲庭 拓

× 稲庭 拓

WEKO 643756

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 643757

en 佐藤 眞二

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 643758

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 In situ visualization of deposited dose distribution is necessary to exploit the advantages of Carbon-ion therapy. Therefore we are developing the world's first, open-type PET "OpenPET" to verify the field irradiated. In addition, a method of utilizing activity measurement in the target irradiated with the beam with positron-emitting radioisotopes (RI) such as 11C and 10C has been proposed. This method has advantage in the amount of activity as well as direct visualization of primary particles themselves, compared with the irradiation with stable nuclei 12C beam. With the RI beam, however, the profile of the dose was still different from that of the activity. Therefore interpretation from activity distribution to dose distribution is necessary to confirm the irradiation field precisely. In this paper, we developed a method of estimating the dose distribution from PET measurements. To utilize the activity measurement of the target, we used the code which calculated the activation distribution and dose distribution taking initial beam energy as a free parameter. Then the maximum likelihood parameter of the initial energy was determined by comparing the measured and the calculated distributions. By using the parameter determined, the dose distribution in the target was calculated as the estimated distribution for the actual one. The uniform PMMA target was irradiated with 11C beam for 10 s. The target was measured from the time beam irradiation started and to 60 s after finishing the irradiation by using a small single-ring OpenPET prototype developed for a proof-of-concept of the in-beam monitoring for charged particle therapy. As a result, the dose distribution, which was originally different from primary particles distribution, was successfully estimated. The peak depth of the estimated dose distribution was in good agreement with the measured dose peak; the estimation error was less than 2 mm.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2013 IEEE NSS/MIC/PTSD
発表年月日
日付 2013-11-02
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:01:25.469691
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3