WEKO3
アイテム
Feasibility study of novel geometry of an axially extendable multiplex cylinder PET
https://repo.qst.go.jp/records/64990
https://repo.qst.go.jp/records/649900bcc5fb3-be0f-4be6-9e62-c1d65fe7ef55
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-05-07 | |||||
タイトル | ||||||
タイトル | Feasibility study of novel geometry of an axially extendable multiplex cylinder PET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Yamaya, Taiga× 吉田 英治× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A current clinical PET scanner has a 15–22 cm axial field-of-view (FOV). These PET scanners image the whole body using about six bed positions. We proposed our original OpenPET geometry which can extend the axial FOV with a limited number of detectors. For an alternative approach, we then designed an axially extendable multiplex cylinder (AEMC) PET scanner to provide high versatility for clinical and research studies using a silicon-photomultiplier (Si-PM)-based depth-of-interaction (DOI) detector. Since Si-PMs have high gain like PMTs and a compact design, the Si-PM-based detector is expected to enable various new detector arrangements. The AEMC-PET scanner consists of four independent and laminated detector rings using a four-layer DOI detector. This PET scanner can extend the axial FOV as each stacked detector ring can be slid aside. When this PET scanner is used for the four-layer DOI detector, its minimum axial FOV is 24 cm and its maximum crystal thickness is 3 cm. On the other hand, the axial FOV can be extended to 96 cm while keeping a continuous detector ring, but the crystal thickness must be 1/4 of 3 cm. In addition, using the OpenPET geometry, the axial FOV can be extended to 168 cm. In this work, we studied the feasibility of the PET scanner with a variable axial FOV using Monte Carlo simulation. For the 180-cm line source simulation, the 96-cm axial FOV was obtained with twofold better sensitivity compared to the 24-cm axial FOV. Also, we showed that the AEMC-PET scanner had a continuous axial FOV to 168 cm. We expect the AEMC-PET scanner will provide high versatility such as for measuring trace whole-body uptakes while keeping the continuous axial FOV and the scan time for static images will be reduced with a limited number of detectors. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2nd SNU-NIRS Workshop on Nuclear Medicine Imaging Science and Technology | |||||
発表年月日 | ||||||
日付 | 2013-04-25 | |||||
日付タイプ | Issued |