Monte Carlo simulation of real-time tumor tracking by the OpenPET using the 4D XCAT phantom with a realistic 18F-FDG distribution

https://repo.qst.go.jp/records/64986
https://repo.qst.go.jp/records/64986
f7a94275-ab70-4126-a9d6-1f251fc9b1b0
Item type 会議発表用資料 / Presentation(1)
公開日 2013-05-02
タイトル
タイトル Monte Carlo simulation of real-time tumor tracking by the OpenPET using the 4D XCAT phantom with a realistic 18F-FDG distribution
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tashima, Hideaki

× Tashima, Hideaki

WEKO 640348

Tashima, Hideaki

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 640349

Yoshida, Eiji

Search repository
Shinaji, Tetsuya

× Shinaji, Tetsuya

WEKO 640350

Shinaji, Tetsuya

Search repository
Hirano, Yoshiyuki

× Hirano, Yoshiyuki

WEKO 640351

Hirano, Yoshiyuki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 640352

Nishikido, Fumihiko

Search repository
Haneishi, Hideaki

× Haneishi, Hideaki

WEKO 640353

Haneishi, Hideaki

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 640354

Ito, Hiroshi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 640355

Yamaya, Taiga

Search repository
田島 英朗

× 田島 英朗

WEKO 640356

en 田島 英朗

Search repository
吉田 英治

× 吉田 英治

WEKO 640357

en 吉田 英治

Search repository
品地 哲弥

× 品地 哲弥

WEKO 640358

en 品地 哲弥

Search repository
平野 祥之

× 平野 祥之

WEKO 640359

en 平野 祥之

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 640360

en 錦戸 文彦

Search repository
羽石 秀昭

× 羽石 秀昭

WEKO 640361

en 羽石 秀昭

Search repository
伊藤 浩

× 伊藤 浩

WEKO 640362

en 伊藤 浩

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 640363

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing OpenPET which can provide an open space observable and accessible to the patient during PET studies. In addition, we have proposed real-time imaging system for the OpenPET which is expected to be used in PET-guided tumor tracking radiation therapy. The tracking ability of the system has been demonstrated using a point source and a small OpenPET prototype. However, tumor tracking in human body still remains as a challenging task when we use PET tracer for tumors because the number of counts in short time frame is small and noises from background activity, scatter and attenuation are unavoidable. In this study, we assess conditions under which tumor tracking is feasible in the human body by using the 4D XCAT phantom which is a realistic 4D human whole body phantom. We conducted Monte Carlo simulation of a human-sized OpenPET geometry by using GATE toolkit assigning typical SUVs in 18F-FDG study to normal organs based on the literature. As a result, we showed that tumor tracking by the OpenPET is feasible even in the human body scale and for realistic conditions when the tumor contains enough radioactivity.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2nd SNU-NIRS workshop on nuclear medicine imaging science and technology
発表年月日
日付 2013-04-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:05:20.911856
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3