Diagnostic Reliability and Validity of Ultrasonographic Tissue Quantification using Acoustic Radiation Force Impulse (ARFI) Elastography - Phantom Study

https://repo.qst.go.jp/records/64862
https://repo.qst.go.jp/records/64862
f833fed2-4f42-4640-b3e5-9bf6722455ce
Item type 会議発表用資料 / Presentation(1)
公開日 2012-12-03
タイトル
タイトル Diagnostic Reliability and Validity of Ultrasonographic Tissue Quantification using Acoustic Radiation Force Impulse (ARFI) Elastography - Phantom Study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kishimoto, Riwa

× Kishimoto, Riwa

WEKO 639213

Kishimoto, Riwa

Search repository
Koyama, Atsuhisa

× Koyama, Atsuhisa

WEKO 639214

Koyama, Atsuhisa

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 639215

Obata, Takayuki

Search repository
Omatsu, Tokuhiko

× Omatsu, Tokuhiko

WEKO 639216

Omatsu, Tokuhiko

Search repository
Suga, Mikio

× Suga, Mikio

WEKO 639217

Suga, Mikio

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 639218

Kandatsu, Susumu

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 639219

Kamada, Tadashi

Search repository
岸本 理和

× 岸本 理和

WEKO 639220

en 岸本 理和

Search repository
小畠 隆行

× 小畠 隆行

WEKO 639221

en 小畠 隆行

Search repository
尾松 徳彦

× 尾松 徳彦

WEKO 639222

en 尾松 徳彦

Search repository
神立 進

× 神立 進

WEKO 639223

en 神立 進

Search repository
鎌田 正

× 鎌田 正

WEKO 639224

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE
To assess the reliability and validity of shear wave velocity measurement of originally-made phantom using acoustic radiation force impulse (ARFI) technology in comparison with physically estimated velocity.
METHOD AND MATERIALS
We made gel phantoms in polyacrylamide hydrogel (storage modulus: 3.1/6.8/16/25kPa) and measured their shear wave velocity by mechanically fixed probe and by two operators (radiologist (Rd) and student (St)) manually ten times each. Shear wave velocity was measured with 4MHz convex (4C) and 9MHz linear (9L) probe using the application of virtual touch tissue quantification. We evaluated the reliability of shear wave velocity measurement with interclass correlation coefficient (ICC) and assessed the variation of shear wave velocity in examination status; probe/frequency, depth of region of interest (ROI), compression pressure and rigidity of phantom. We also compared shear wave velocity with physically estimated velocity.
RESULTS
The reliability of mechanically fixed measurement was extremely high both with 4C/9L (ICC:0.987/1.0). Intra-operator reliability of manually measurement was extremely high with 9L (ICC: Rd0.998/St0.999) and considerably high with 4C (ICC: Rd0.897/St0.957) by ten times measurement. With 9L probe, once measurement was enough and 3~5 times measurements were needed with 4C probe for high reliability. Inter-operator reliability was also very high (ICC:0.989). Shear wave velocity increased significantly with strengthening of compression pressure both with 4C/9L. There is no significant difference in depth of ROI with mechanically fixed measurement but with manually measurement, shear wave velocity was higher at deeper ROI. Shear wave velocity was approximate to physically estimated value with 9L probe but it was 15~30% lower than estimated value when we measured a firmer phantom with 4C probe.
CONCLUSION
Although the reliability of shear wave velocity measurement was high enough, measured velocity varied among measurement status and differed from physically estimated velocity up to 30%. We need to understand these peculiarities and particular attention should be given when we compare shear wave velocity with the other measurement value.
CLINICAL RELEVANCE/APPLICATION
Although the reliability of shear wave velocity measurement was considerably high, shear wave velocity varied among measurement status and was not always equivalent to physically estimated velocity.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 98th Scientific Assembly and Annual Meeting
発表年月日
日付 2012-11-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:06:45.338246
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3