Feasibility study of an axially extendable multiplex cylinder PET
https://repo.qst.go.jp/records/64837
https://repo.qst.go.jp/records/648370a311a9b-4c5a-43ff-8fbc-8356c3ca4a10
| Item type | 会議発表用資料 / Presentation(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2012-11-16 | |||||
| タイトル | ||||||
| タイトル | Feasibility study of an axially extendable multiplex cylinder PET | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
| 資源タイプ | conference object | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Yoshida, Eiji
× Yoshida, Eiji× Hirano, Yoshiyuki× Tashima, Hideaki× Inadama, Naoko× Nishikido, Fumihiko× Murayama, Hideo× Ito, Hiroshi× Yamaya, Taiga× 吉田 英治× 平野 祥之× 田島 英朗× 稲玉 直子× 錦戸 文彦× 村山 秀雄× 伊藤 浩× 山谷 泰賀 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A conventional PET scanner has a 15–25 cm axial field-of-view (FOV) and images the whole body using about six bed positions. We proposed our original OpenPET geometry which can extend the axial FOV with a limited number of detectors. For an alternative approach, we then designed an axially extendable multiplex cylinder (AEMC) PET scanner to provide high versatility for clinical and research studies using a silicon-photomultiplier (Si-PM)-based DOI detector. Since Si-PMs have high gain like PMTs and a compact design, the Si-PM-based detector is expected to enable various new detector arrangements. The AEMC-PET scanner consists of four independent and laminated detector rings using a four-layer depth-of-interaction (DOI) detector. This PET scanner can extend the axial FOV as each stacked detector ring can be slid aside. When this scanner is used for the four-layer DOI detector, its minimum axial FOV is 24 cm and its maximum crystal thickness is 3 cm. On the other hand, the axial FOV can be extended to 96 cm while keeping a continuous axial FOV, but the crystal thickness must be 1/4 of 3 cm. In addition, using the OpenPET geometry, the axial FOV can be extended to 168 cm. In this work, we studied the feasibility of the PET scanner with a variable axial FOV using Monte Carlo simulation. For the 180-cm line source simulation, the 96-cm axial FOV was obtained with twofold better sensitivity compared to the 24-cm axial FOV. Also, we showed that the AEMC-PET scanner had a continuous axial FOV to 168 cm. We expect the AEMC-PET scanner will provide high versatility such as for measuring trace whole-body uptakes while keeping the continuous axial FOV and the scan time for static images will be reduced with a limited number of detectors. | |||||