Preliminary results of water shielding effects for space radiation in ISS crew cabin by means of passive dosimeters

https://repo.qst.go.jp/records/64675
https://repo.qst.go.jp/records/64675
430310b3-909f-412c-890a-924fa7b57657
Item type 会議発表用資料 / Presentation(1)
公開日 2012-07-23
タイトル
タイトル Preliminary results of water shielding effects for space radiation in ISS crew cabin by means of passive dosimeters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 637373

Kodaira, Satoshi

Search repository
et.al

× et.al

WEKO 637374

et.al

Search repository
小平 聡

× 小平 聡

WEKO 637375

en 小平 聡

Search repository
抄録
内容記述タイプ Abstract
内容記述 The dose reduction rate for space radiation by the additional installation of water shielding (the hygienic wipes and towels containing water) in ISS crew cabin was measured with the passive dosimeter packages consisting of thermoluminescence detector (TLDs) and CR-39 plastic nuclear track detectors (PNTD). The water shieldings were stored into the protective curtain at 4 layers, which is corresponding to the additional shielding thickness of about 8 g/cm2. The total mass of the protective curtain was to be 65 kg. That was installed along the outer wall of the starboard crew cabin in Russian Service Module. The dose reduction effect by water shielding was experimentally measured with the totally 12 passive dosimeter packages. Half of packages were located on the protective curtain surface and the other half packages were located on the crew cabin wall behind or aside the protective curtain. Two experiments for different duration were carried out onboard ISS crew cabin, 1) from July 4 to November 29, 2010 and 2) from December 17, 2010 to May 5, 2011. The dose reduction rate by the protective curtain was ranging from 15 to 70 % in absorbed dose due depending on the material thickness. We also tried to compare the results with the calculation based on Mote Carlo simulation. It is expected that the properly utilization of protective curtain would effectively reduce the radiation dose for crew living in space station.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 39th COSPAR Scientific Assembly
発表年月日
日付 2012-07-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:08:55.305903
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3