ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo

https://repo.qst.go.jp/records/64638
https://repo.qst.go.jp/records/64638
9d8433c2-e7dd-4c23-9052-d3e3b14c292a
Item type 会議発表用資料 / Presentation(1)
公開日 2012-06-22
タイトル
タイトル Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sai, Sei

× Sai, Sei

WEKO 636992

Sai, Sei

Search repository
Oonishi, Kazuhiko

× Oonishi, Kazuhiko

WEKO 636993

Oonishi, Kazuhiko

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 636994

Yamada, Shigeru

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 636995

Kamada, Tadashi

Search repository
崔 星

× 崔 星

WEKO 636996

en 崔 星

Search repository
大西 和彦

× 大西 和彦

WEKO 636997

en 大西 和彦

Search repository
山田 滋

× 山田 滋

WEKO 636998

en 山田 滋

Search repository
鎌田 正

× 鎌田 正

WEKO 636999

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
To investigate whether a carbon ion beam has beneficial effects compared to X-rays by targeting putative human pancreatic cancer stem cells.
Materials
Human pancreatic cancer stem-like cells sorted from MiaPaca2, BxPc3, PANC1 and PK45 cells were treated with or without carbon ion or X-ray irradiation and then colony formation assay, spheroid formation assay, FACS analysis, as well as tumor formation analysis were performed.
Results
The relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for above pancreatic cancer cells at the D10 values were 1.71-2.18. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like cells CD44-/CD24-cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0-2.19. The number of gammaH2AX foci in CD44-/CD24- cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of gammaH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists for significantly longer in carbon ion beam irradiated cells compared to X-rays.
Conclusion
Carbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 51st Annual Meeting of Particle Therapy Co-Operative Group (PTCOG51)
発表年月日
日付 2012-05-19
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:09:20.415086
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3