WEKO3
アイテム
Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo
https://repo.qst.go.jp/records/64638
https://repo.qst.go.jp/records/646389d8433c2-e7dd-4c23-9052-d3e3b14c292a
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-06-22 | |||||
タイトル | ||||||
タイトル | Effects of Carbon Ion Beam on Pancreatic Cancer Stem-Like Cells In Vitro and In Vivo | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sai, Sei
× Sai, Sei× Oonishi, Kazuhiko× Yamada, Shigeru× Kamada, Tadashi× 崔 星× 大西 和彦× 山田 滋× 鎌田 正 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose To investigate whether a carbon ion beam has beneficial effects compared to X-rays by targeting putative human pancreatic cancer stem cells. Materials Human pancreatic cancer stem-like cells sorted from MiaPaca2, BxPc3, PANC1 and PK45 cells were treated with or without carbon ion or X-ray irradiation and then colony formation assay, spheroid formation assay, FACS analysis, as well as tumor formation analysis were performed. Results The relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for above pancreatic cancer cells at the D10 values were 1.71-2.18. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like cells CD44-/CD24-cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0-2.19. The number of gammaH2AX foci in CD44-/CD24- cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of gammaH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists for significantly longer in carbon ion beam irradiated cells compared to X-rays. Conclusion Carbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 51st Annual Meeting of Particle Therapy Co-Operative Group (PTCOG51) | |||||
発表年月日 | ||||||
日付 | 2012-05-19 | |||||
日付タイプ | Issued |