Gamma-ray Measurement using Pulse Shape Discrimination with NaI(Tl) Scintillator Under p-Li Neutron Beam

https://repo.qst.go.jp/records/64272
https://repo.qst.go.jp/records/64272
d9662e12-02f9-42eb-ad53-5352a76a54ad
Item type 会議発表用資料 / Presentation(1)
公開日 2011-07-20
タイトル
タイトル Gamma-ray Measurement using Pulse Shape Discrimination with NaI(Tl) Scintillator Under p-Li Neutron Beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kamada, So

× Kamada, So

WEKO 633853

Kamada, So

Search repository
et.al

× et.al

WEKO 633854

et.al

Search repository
鎌田 創

× 鎌田 創

WEKO 633855

en 鎌田 創

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have a chance of gamma ray and neutron exposure at nuclear accidents, around high-energy accelerator and in aircrafts. For gamma-ray dose evaluation, we have to measure gamma-ray energy spectrum separately from neutrons. Gamma-ray detectors cannot measure gamma rays discriminated from neutrons, and neutron events are observed in the gamma-ray detectors. We have to separate gamma-ray efficiency and good energy resolution of 6.9% at gamma-ray energy of 662 keV.
We are able to measure gamma rays separately from neutrons using pulse shape discrimination with the NaI(Tl) scintillator. The NaI(Tl) scintillator is useful to measure gamma rays under the neutron fields. We measured neutrons and gamma rays produced by Li(p, xn) reactions at the cyclotron facility in National Institute of Radiological Sciences in Japan. Additionaly we obtain neutron energy spectrum with Time Of Flight (TOF) method using an organic liquid scintillator, EJ-399-06 with 5.08-cm diameter and 5.08-cm length. Neutrons are discriminated from gamma rays using different pulse shapes. Quasi-mono energetic neutron energy spectrum was measured with 39 MeV-peak and 4 MeV FWHM.
We use the NaI(Tl) scintillator of 5.08 diameter and 5.08 cm length. We can discriminate gamma rays from neutrons, clearly. With TOF method, we obtained prompt gamma ray and scattered and detector activated events. We will obtain gamma-ray energy spectrum and ambient dose equivalents, separately from neutron events under high-energy neutron fields. Our method is useful to subtract background due to cosmic rays, and to measure cross sections of gamma-ray production and angular distributions.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 the Sixth International Symposium on Radiation Safety and Detection Technology (ISORD-6)
発表年月日
日付 2011-07-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:13:30.914786
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3