ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Precise determination of Pu isotopes in a newly certified seawater reference material IAEA-443 using isotope-dilution SF-ICP-MS

https://repo.qst.go.jp/records/64238
https://repo.qst.go.jp/records/64238
3b27a364-dbfc-4217-be1a-7bdb7124c06b
Item type 会議発表用資料 / Presentation(1)
公開日 2011-03-09
タイトル
タイトル Precise determination of Pu isotopes in a newly certified seawater reference material IAEA-443 using isotope-dilution SF-ICP-MS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zheng, Jian

× Zheng, Jian

WEKO 633534

Zheng, Jian

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 633535

Yamada, Masatoshi

Search repository
鄭 建

× 鄭 建

WEKO 633536

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 633537

en 山田 正俊

Search repository
抄録
内容記述タイプ Abstract
内容記述 For the quality control of analytical data of anthropogenic radionuclides in marine environment, reference material is important for method development and validation. A series of reference materials for all important marine matrices, such as sediment, biota, seawater and suspended matter have been issued by IAEA for anthropogenic radionuclide analysis. Among them, IAEA-381 (seawater from the Irish Sea) was widely used for seawater analysis. Recently, IAEA produced a new Irish Sea seawater reference material, the IAEA-443, as the IAEA-381 has already been sold out. We participated the interlaboratory comparison tests organized by the IAEA Marine Environment Laboratory in Monaco for the certification of this new reference material. In order to obtain precise Pu isotope composition of Irish Sea water reference material, we analyzed the activities of 239Pu, 240Pu, 239+240Pu, 241Pu, the atom ratio of 240Pu/239Pu, and the activity ratio of 241Pu/239+240Pu by a highly sensitive isotope dilution SF-ICP-MS method combined with two-stage chromatographic separation and purification. Detailed results of Pu activity and isotope composition will be reported. With a mean chemical yield of 65 % for 242Pu tracer, we found that the experimentally established values for 239Pu, 240Pu, 241Pu and 239+240Pu activities are almost the same as those in the IAEA-381 seawater reference material. Regarding the 239+240Pu activity, we provided the most precise and accurate result among the twelve laboratories participated in the interlaboratory comparison.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第12回 「環境放射能」研究会
発表年月日
日付 2011-03-10
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:13:53.897174
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3