ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Prognostic Value of ADC: Malignant Astrocytic Tumors after Carbon Ion Radiotherapy

https://repo.qst.go.jp/records/64204
https://repo.qst.go.jp/records/64204
f57fb1e0-fb2a-4774-bb38-bea51afdda55
Item type 会議発表用資料 / Presentation(1)
公開日 2011-02-02
タイトル
タイトル Prognostic Value of ADC: Malignant Astrocytic Tumors after Carbon Ion Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kishimoto, Riwa

× Kishimoto, Riwa

WEKO 633213

Kishimoto, Riwa

Search repository
Omatsu, Tokuhiko

× Omatsu, Tokuhiko

WEKO 633214

Omatsu, Tokuhiko

Search repository
Hasegawa, Azusa

× Hasegawa, Azusa

WEKO 633215

Hasegawa, Azusa

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 633216

Kandatsu, Susumu

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 633217

Mizoe, Junetsu

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 633218

Kamada, Tadashi

Search repository
岸本 理和

× 岸本 理和

WEKO 633219

en 岸本 理和

Search repository
尾松 徳彦

× 尾松 徳彦

WEKO 633220

en 尾松 徳彦

Search repository
長谷川 安都佐

× 長谷川 安都佐

WEKO 633221

en 長谷川 安都佐

Search repository
神立 進

× 神立 進

WEKO 633222

en 神立 進

Search repository
溝江 純悦

× 溝江 純悦

WEKO 633223

en 溝江 純悦

Search repository
鎌田 正

× 鎌田 正

WEKO 633224

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: Carbon ion radiotherapy often induces radiation brain injury in various degrees and differentiation of recurrent tumor from radiation injury on follow-up MR images is problematic. Recently it has been reported that assessment of apparent diffusion coefficients (ADCs) of enhancing regions was useful in differentiation between recurrent glioma and radiation injury. The purpose of this study is to assess the relationship between ADC value and prognosis of patients with malignant astrocytic tumors after carbon ion radiotherapy retrospectively and to evaluate the prognostic value of ADC
METHOD AND MATERIALS: Twenty-five patients who underwent diffusion weighted imaging (DWI) in follow-up MR examination after carbon ion radiotherapy for malignant astrocytic tumors were enrolled in this study. We evaluated the most recent MR examination in our institution. MR imaging was performed using a 1.5T MRI unit with a head coil. DWI in the axial direction was obtained by using a STIR-EPI sequence with b-values of 0 and 1,000 sec/mm2, acquired in three orthogonal directions. Region of interest (ROIs) were drawn manually onto the obtained ADC maps in the region corresponding to the enhancing area on contrast-enhanced T1-weighted images. Statistical analysis was performed with SPSS. Mean ADC values between fatality group and survival group were compared using Mann-Whitney U test.
RESULTS: One survival patient in whom local recurrence could not be denied because of short follow-up period was excluded from this study. Fatality group included 16 cases and survival group included eight cases. Fatality group included three patients who died from other cause than recurrence. All surviving patients were followed up for more than 3 years and their intracranial lesions were thought to be brain injury. Mean ADC value of fatality group (1.13+0.15[x10-3mm2/sec]) was significantly smaller than those of survival group (1.50+0.26) (p<0.01) . When we used a cutoff value of 1.3 for suspecting prognosis on mean ADC values (i.e., patient with ADC<1.3 would die from recurrence), positive predictive value was 86.7% and negative predictive value was 88.9%.
CONCLUSION: For malignant astrocytic tumors after carbon-ion radiotherapy, cases with intracranial lesions of ADC value smaller than 1.3 are suspected to have poor prognosis.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 96th Scientific Assembly and Annual Meeting
発表年月日
日付 2010-12-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:14:16.838282
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3