ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

[18F]FDG-PET STUDIES OF HETEROTOPIC HEART TRANSPLANTATION IN RATS

https://repo.qst.go.jp/records/64022
https://repo.qst.go.jp/records/64022
27d7a3df-90d3-4ddd-b46f-e51acc47e08e
Item type 会議発表用資料 / Presentation(1)
公開日 2010-09-27
タイトル
タイトル [18F]FDG-PET STUDIES OF HETEROTOPIC HEART TRANSPLANTATION IN RATS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inubushi, Masayuki

× Inubushi, Masayuki

WEKO 631593

Inubushi, Masayuki

Search repository
Hatayama, Naoyuki

× Hatayama, Naoyuki

WEKO 631594

Hatayama, Naoyuki

Search repository
Nan, Jin Yong

× Nan, Jin Yong

WEKO 631595

Nan, Jin Yong

Search repository
Koizumi, Mitsuru

× Koizumi, Mitsuru

WEKO 631596

Koizumi, Mitsuru

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 631597

Saga, Tsuneo

Search repository
et.al

× et.al

WEKO 631598

et.al

Search repository
犬伏 正幸

× 犬伏 正幸

WEKO 631599

en 犬伏 正幸

Search repository
畑山 直之

× 畑山 直之

WEKO 631600

en 畑山 直之

Search repository
金 永男

× 金 永男

WEKO 631601

en 金 永男

Search repository
小泉 満

× 小泉 満

WEKO 631602

en 小泉 満

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 631603

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 We developed a novel hyperbarically desiccated preservation method of transplants to cope with the global donor shortage, and have reported that in rats with our method the preservation time could be extended to 72 hours when resumption of beating after cardiac transplantation was defined as successful preservation. The purpose of this study was to investigate the effects of preservation time on myocardium using [18F]FDG-PET.
\nMale Lewis rats were used. The hearts were extracted from donor rats, and were immediately exposed to hyperbaric mixed gas (2100 hPa PO2 + 1400 hPa PCO in study group [n=8], or 1400 hPa PO2 + 2100 hPa PCO in negative control [NC] group [n=3]) at 4DegreeC. After 24 or 48 hours of the preservation, the hearts were immersed in physiological saline, and were transplanted to the right neck of recipient rats. The rats received a cardiac transplant immediately after extraction without preservation served as positive control (PC) group (n=7). Within 2 hours after completion of the transplant surgery, the rats were injected with 37 MBq of [18F]FDG intravenously, and underwent PET imaging using a small-animal PET scanner (Siemens Inveon). [18F]FDG-PET imaging was repeated 1 week later. For semiquantitative PET analysis, ratios of the maximal counts of the donor heart (D) to the recipient heart (R) were calculated.
\nIn NC and 48-hour preserved study groups, the [18F]FDG uptake to the donor hearts was low (D/R was 16.8 % and 21.0+/-3.4 %, respectively). On the other hand, the tracer uptake to the donor hearts in 24-hour preserved study group was as high as that in PC group (D/R was 119.3+/-41.9 % and 79.2+/-20.0 %, respectively), although it decreased 1 week later in the both groups (D/R was 60.0+/-26.9 % and 54.8+/-17.8 %, respectively).
\n[18F]FDG-PET studies revealed that with our novel method preservation for up to 24 hours could maintain cell viability of the donor hearts as much as the immediate transplantation. However, the cell viability declined 1 week later not only in the preserved group but also in the immediate transplantation group, which suggested limitation of this animal model in evaluating long-term outcome of the transplants.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 World Federation of Nuclear Medicine and Biology 2010
発表年月日
日付 2010-09-23
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:16:19.238955
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3