Neutron Exposure Accelerator System for Biological Effect Experiments (NASBEE)

https://repo.qst.go.jp/records/63972
https://repo.qst.go.jp/records/63972
c78a7bff-f18c-4ba7-8187-1dbef4a38762
Item type 会議発表用資料 / Presentation(1)
公開日 2010-08-17
タイトル
タイトル Neutron Exposure Accelerator System for Biological Effect Experiments (NASBEE)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takada, Masashi

× Takada, Masashi

WEKO 631196

Takada, Masashi

Search repository
et.al

× et.al

WEKO 631197

et.al

Search repository
高田 真志

× 高田 真志

WEKO 631198

en 高田 真志

Search repository
抄録
内容記述タイプ Abstract
内容記述 MON-MAR01-4 #209 - Contributed Talk - Monday 1:00 PM - Pecos I
Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE)
Masashi Takada, Mitsuru Suda, Takuya Hagiwara, Tsuyoshi Hamano
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba Chiba 263-8555, Japan
Biological studies for neutrons have been performed using the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) in National Institute of Radiological Sciences (NIRS), Chiba, Japan. Neutron biological data are necessary for radiation protections around high-energy accelerators, particle therapy and in aircraft. NIRS have focused to obtain the relative biological effects (RBEs) of several cancers of mice and rats. NASBEE provides the neutron beams produced from the d(4 MeV)-Be reactions at 500 micro-A on the target, cooled by flowing water. The neutron energy spectrum is measured from thermal energy up to 9 MeV and has a shoulder around 2 MeV. Two irradiation rooms can be used: one is normal neutron irradiation rooms for cell and physical irradiation and the other is for specific pathogen-free irradiation. We characterized the neutron irradiation field by measuring absorbed doses using neutron ion chambers, microdosimetric lineal energy distribution using low pressure proportional counters, energy spectra and spatial distributions. The neutron dose rates were measured to be 7.62 mGy/hr. The microdosimetric distributions are closely related to the biological effects of radiations and provides neutron RBEs, 3.5. Photon absorbed doses are contaminated to be 18% in the neutron beams. The neutron doses are within +-5% in the 120 mm in diameter. We are making neutron irradiation system to observe local neutron effect of rats (rat lungs).
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 21st International Conference on the Application of Accelerators in Research and Industry
発表年月日
日付 2010-08-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:16:53.165116
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3