Intrafractional and Interfractional Range Variations in Charged Particle Therapy of Lung Cancer

https://repo.qst.go.jp/records/63781
https://repo.qst.go.jp/records/63781
77a60aef-5237-492a-9aab-f6c7ef42bfc7
Item type 会議発表用資料 / Presentation(1)
公開日 2010-02-09
タイトル
タイトル Intrafractional and Interfractional Range Variations in Charged Particle Therapy of Lung Cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 629385

Mori, Shinichiro

Search repository
et.al

× et.al

WEKO 629386

et.al

Search repository
森 慎一郎

× 森 慎一郎

WEKO 629387

en 森 慎一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background:
To quantify water equivalent pathlength (WEL) variations due to both intrafractional and interfractional changes in anatomy and physical properties through analysis of weekly serial four-dimensional (4D) CT scans.
\nMaterials and Methods:
Serial 4DCT scans were performed under free breathing conditions during 6 weeks of radiotherapy. Evaluation metrics were variations in WEL, lung density, CT number and chest wall thickness. Metrics for the intrafractional variations were evaluated as a function of 10 respiratory phases using 4DCT data sets. For the interfractional changes, metrics from the initial CT scan (week 0) were compared with those from subsequent serial weekly CT scans (weeks 1 to 5) at peak exhalation as the reference.
\nResults:
Mean WEL variations over the internal target volume region for all patients were -7.1mm and -15.5 mm due to intrafractional and interfractional changes, respectively. Chest wall thickness variations of < -3.0 mm, -3.6 mm, -3.6 mm were observed during respiration in the upper, middle and lower lung regions respectively. WEL variations of -7.2 mm, -6.5 mm, -4.3 mm in the upper, middle and lower lung were observed in the interfractional data. Lung density and soft tissue CT numbers did not show significant changes. Chest wall thickness showed variation from week to week; these variations could be attributed to patient setup in particular, maintaining the arm-up position can be a challenge for physically weak cancer patients. In addition, the WEL values decreased gradually through the treatment course. This trend could be explained by weight loss, muscle atrophy, lymphadenopathy, etc.
\nConclusions:
Chest wall thickness change was identified as the greatest common factor among all patients affecting range variations, potentially resulting in beam overshoot in charged particle therapy. Replanning and redesigning the compensating bolus may be necessary to better conform the prescribed dose to the target and minimize normal tissue irradiation. In addition, immobilization and better reproducibility of the arm position may be important to minimize the changes in chest wall thickness, especially the upper chest region.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG48
発表年月日
日付 2009-10-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:19:04.255294
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3