ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Radiosensitivity in mesothelioma cell lines for X rays and carbon-ion beams

https://repo.qst.go.jp/records/63214
https://repo.qst.go.jp/records/63214
4cb4635f-a3cd-4419-93d2-5b14c56fbb38
Item type 会議発表用資料 / Presentation(1)
公開日 2009-08-31
タイトル
タイトル Radiosensitivity in mesothelioma cell lines for X rays and carbon-ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hua, Liu Cui

× Hua, Liu Cui

WEKO 624307

Hua, Liu Cui

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 624308

Suzuki, Masao

Search repository
Tsuruoka, Chizuru

× Tsuruoka, Chizuru

WEKO 624309

Tsuruoka, Chizuru

Search repository
Nojima, Kumie

× Nojima, Kumie

WEKO 624310

Nojima, Kumie

Search repository
et.al

× et.al

WEKO 624311

et.al

Search repository
劉 翠華

× 劉 翠華

WEKO 624312

en 劉 翠華

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 624313

en 鈴木 雅雄

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 624314

en 鶴岡 千鶴

Search repository
野島 久美恵

× 野島 久美恵

WEKO 624315

en 野島 久美恵

Search repository
抄録
内容記述タイプ Abstract
内容記述 Malignant pleural mesothelioma (MPM) is an aggressive tumor arising from serous surfaces and often related to asbestos exposure. Taking into account a latency period of 20-40 years, it has been estimated that the number of men dying from MPM increase each year until a peak is reached in about 2020. MPM is resistant to various forms of therapy, such as radiotherapy, surgery or chemotherapy, and only slightly improve prognosis. So far, no effective therapeutics including chemotherapy or radiotherapy has been established for the disease-advanced case. The present study was carried out in order to examine the radiosensitivity of MPM cell lines by X rays and carbon-ion beams. Officially distributed 6 kinds of MPM cell lines were used and irradiated with X rays or carbon-ion beams (13.3keV/µm and approximately 80keV/µm) at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Cell-killing effect was detected using a colony-formation assay. D10, which is one of the parameters for cellular radiosensitivity, of 6 cell lines ranges from 2.74Gy to 5.42Gy for X rays, 2.17Gy to 4.21Gy for 13keV/µm- and 1.08Gy to 2.38Gy for 80keV/µm-carbon ions. The relative biological effectiveness (RBE) values calculated by the D10 relative to X rays, ranges from 1.24 to 1.42 for 13keV/µm- and from 2.31 to 3.09 for approximate 80keV/µm-carbon ions on each cell line. The results suggest that the irradiation of high LET carbon ions are also significantly more effective in cell killing for the 6 kinds of MPM cell lines than that of low LET X rays.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NIRS-IMP joint symposium on carbon ion therapy
発表年月日
日付 2009-08-15
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:21:54.378838
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3