ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Frequency of dicentric chromosome in spleen from the mice exposed to low dose rate radiation and/or chemicals.

https://repo.qst.go.jp/records/62913
https://repo.qst.go.jp/records/62913
3061a021-1f98-49a2-a785-0b1132b65935
Item type 会議発表用資料 / Presentation(1)
公開日 2008-12-10
タイトル
タイトル Frequency of dicentric chromosome in spleen from the mice exposed to low dose rate radiation and/or chemicals.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Mitsuaki

× Yoshida, Mitsuaki

WEKO 621464

Yoshida, Mitsuaki

Search repository
Akiyma, Miho

× Akiyma, Miho

WEKO 621465

Akiyma, Miho

Search repository
Masumura, Kenichi

× Masumura, Kenichi

WEKO 621466

Masumura, Kenichi

Search repository
Nohmi, Takehiko

× Nohmi, Takehiko

WEKO 621467

Nohmi, Takehiko

Search repository
Hayata, Isamu

× Hayata, Isamu

WEKO 621468

Hayata, Isamu

Search repository
Ono, Tetsuya

× Ono, Tetsuya

WEKO 621469

Ono, Tetsuya

Search repository
吉田 光明

× 吉田 光明

WEKO 621470

en 吉田 光明

Search repository
穐山 美穂

× 穐山 美穂

WEKO 621471

en 穐山 美穂

Search repository
増村 健一

× 増村 健一

WEKO 621472

en 増村 健一

Search repository
能美 健彦

× 能美 健彦

WEKO 621473

en 能美 健彦

Search repository
早田 勇

× 早田 勇

WEKO 621474

en 早田 勇

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to investigate the effect of low dose rate radiation and to evaluate the
combined effects of chemicals and radiation, chromosomes were analyzed in spleen
cells from the mice exposed to low dose rate radiation for a long periods and also from the mice treated with tobacco-specific nitrosamine NNK and radiation. Chromosomes were prepared from the spleen cells in F1 mice between gpt delta transgenic and SWR strains after irradiation for 483 days.
The total dose in these mice were OGy, 20mGy (0.04255 mGy/day), 400mGy (0.858 mGy/day) and 8Gy(16.56mGy/day). Frequencies of dicentric chromosome (die) per cell at each dose were 0.00042 (OGy), 0.00118(20mGy), 0.00233 (400mGy) and 0.02261 (8Gy), respectively. It may be worth to be mentioned that die was detected in mice irradiated at the lowest dose, 20mGy (dose rate: 0.04255mGy/day), although it was not significant statistically.
It may be also important that the frequency of die was increasing according to the total dose.
In the present study, we also analyzed chromosomes in gpt delta transgenic mice
treated with irradiation at a dose rate of0.5, 1.0, 1.5 mGy for 22h /day for 31days and NNK at a dose of 2mg/mouse/day. NNK treatment was performed for four days in the middle course of irradiation; Frequencies of dicentric per cells in mice exposed to only radiation were 0.0049 (OGy), 0.0039 (0.5mGy/day), 0.0134 (l.OmGy/day) and 0.0114(1.5mGy/day), respectively. On the other hand, frequencies of die in mice treated with NNK and radiation were 0 (OGy+NNK), 0.0031 (0.5mGy/day+NNK), 0.0045
(l.OmGy/day+NNK) and 0.00112 (1.5mGy/day+NNK). Thus, there was no
enhancement in the frequency of die in mice with combined treatment. Further
chromosome analysis should be performed in an increased number of metaphase.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 New Nuclear Research Symposium "Biological Responses to Low Dose Radiation"
発表年月日
日付 2008-11-19
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:25:18.258387
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3