Evaluation of Average Glandular Doses in Digital Mammography

https://repo.qst.go.jp/records/62730
https://repo.qst.go.jp/records/62730
d85749f3-b257-429f-aa8e-9a4bdbf6598c
Item type 会議発表用資料 / Presentation(1)
公開日 2008-09-19
タイトル
タイトル Evaluation of Average Glandular Doses in Digital Mammography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fujii, Keisuke

× Fujii, Keisuke

WEKO 619591

Fujii, Keisuke

Search repository
Ko, Susumu

× Ko, Susumu

WEKO 619592

Ko, Susumu

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 619593

Nishizawa, Kanae

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 619594

Akahane, Keiichi

Search repository
Iwai, Kazuo

× Iwai, Kazuo

WEKO 619595

Iwai, Kazuo

Search repository
Matsumoto, Masao

× Matsumoto, Masao

WEKO 619596

Matsumoto, Masao

Search repository
藤井 啓輔

× 藤井 啓輔

WEKO 619597

en 藤井 啓輔

Search repository
幸 進

× 幸 進

WEKO 619598

en 幸 進

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 619599

en 西澤 かな枝

Search repository
赤羽 恵一

× 赤羽 恵一

WEKO 619600

en 赤羽 恵一

Search repository
岩井 一男

× 岩井 一男

WEKO 619601

en 岩井 一男

Search repository
松本 政雄

× 松本 政雄

WEKO 619602

en 松本 政雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, digital mammography units have been introduced into clinical use in Japan and patients undergoing digital mammography have been increasing. Because breast is relatively sensitive to radiation among organs, the evaluation of average glandular dose (AGD) in digital mammography is important for the optimization of exposure parameters and the assessment of the risk to radiation-induced cancer. The aim of this study is to evaluate the AGD for digital mammography performed in several medical facilities and to suggest the method of reducing doses with maintaining diagnostic image quality. We measured the exposure doses at entrance surface of the each phantom using four types of digital mammographic units and two types of phantoms consisting of 50% glandular and 50% adipose tissue, and evaluated the AGD per image from the product of the entrance surface doses and the conversion factor for glandular tissue. The AGD evaluated with the RMI 156 phantom were 1.7 - 2.1 mGy for the tube voltage of 28kV, and the target/filter combination of Mo/Mo, which were slightly higher than those in screen/film mammography. For breast thickness of 3.8 cm corresponding to mean compressed breast thickness of Japanese patients, the AGD evaluated with the BR-12 phantom were 1.2 – 1.6mGy. The wide variation of doses among digital mammographic units will cause the difference of the x-ray beam energy and mAs determined by the auto exposure control system. The AGD for Japanese patients in digital mammography were slightly higher than those in conventional screen/film mammography because Mo/Mo was still mainly used in digital mammography and mAs selected in digital systems was higher than that in screen/film systems. The AGD for Japanese patients can also be reduced by the use of harder x-ray beam and smaller mAs without affecting diagnostic image quality.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 5th KOREA-JAPAN Joint Meeting on Medical Physics
発表年月日
日付 2008-09-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:27:26.626868
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3