ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Measurement of Surgeon's Dose during 125I Brachytherapy for Treatment of Prostate Cancer

https://repo.qst.go.jp/records/62729
https://repo.qst.go.jp/records/62729
0d945f55-0f1f-4c9f-8f07-b2b6276ef8b8
Item type 会議発表用資料 / Presentation(1)
公開日 2008-09-19
タイトル
タイトル Measurement of Surgeon's Dose during 125I Brachytherapy for Treatment of Prostate Cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ko, Susumu

× Ko, Susumu

WEKO 619589

Ko, Susumu

Search repository
幸 進

× 幸 進

WEKO 619590

en 幸 進

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since the authorization of brachytherapy using 125I seeds for prostate cancer treatment in 2002 in Japan, the number of this procedure has been increasing. While this procedure has shown its effectiveness, it has been suspected that frequent operations by a single surgeon might cause over-exposures. To ensure surgeon's safety from the viewpoint of radiation protection, we conducted the measurements of surface doses of medical personnel during the procedures. The measurements were performed with TLDs and glass dosemeters applied to various points of the surgeon during 125I brachytherapy operations. The sensitivities of those dosemeters were calibrated for photon beam at corresponding energy (approximately 30 keV). The results of the measurements repeated for 20 times since February 2007 to May 2008 at a hospital showed surface doses on the surgeon ranged up to 650 uGy. They were far below the dose level causing deterministic effects on the skin. It was also shown that utilization of protective gloves (Pb 0.03 mm equivalent) reduced the doses to hands effectively. The surface doses of a surgeon tended to decrease possibly due to improved proficiency during the series of measurements. As a conclusion, the annual accumulated dose is not likely to reach the dose limit if sufficient attention is paid to radiation protection like these studied cases.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 5th KOREA-JAPAN Joint Meeting on Medical Physics
発表年月日
日付 2008-09-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:27:27.286119
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3