ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Carbon Ion Radiotherapy for Eye Tumor

https://repo.qst.go.jp/records/62491
https://repo.qst.go.jp/records/62491
51b181ec-4944-404a-a730-0214d9a7ccc8
Item type 会議発表用資料 / Presentation(1)
公開日 2008-03-26
タイトル
タイトル Carbon Ion Radiotherapy for Eye Tumor
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 617389

Tsuji, Hiroshi

Search repository
Kato, Hiroyuki

× Kato, Hiroyuki

WEKO 617390

Kato, Hiroyuki

Search repository
Yanagi, Takeshi

× Yanagi, Takeshi

WEKO 617391

Yanagi, Takeshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 617392

Kamada, Tadashi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 617393

Tsujii, Hirohiko

Search repository
辻 比呂志

× 辻 比呂志

WEKO 617394

en 辻 比呂志

Search repository
加藤 弘之

× 加藤 弘之

WEKO 617395

en 加藤 弘之

Search repository
柳 剛

× 柳 剛

WEKO 617396

en 柳 剛

Search repository
鎌田 正

× 鎌田 正

WEKO 617397

en 鎌田 正

Search repository
辻井 博彦

× 辻井 博彦

WEKO 617398

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To evaluate the applicability of carbon ion beams in the treatment of choroidal melanoma, with regard to normal tissue morbidity and local tumor control.
Methods and Materials: Between January 2001 and August 2007, 78 patients with a locally advanced or of unfavorable site choroidal melanoma were enrolled to a phase I/II clinical trial of carbon-ion radiotherapy (C-ion RT) at the National Institute of Radiological Sciences (NIRS). Primary endpoint of this study was normal tissue morbidity and secondary endpoints were local tumor control and patient survival. Of those, 72 patients were followed up more than 6 months and analyzed.
Results: Twenty-six patients (36%) have developed neovascular glaucoma and 3 of them received enucleation because of eye pain due to elevated intraocular pressure. Incidence of neovascular glaucoma was dependent on the tumor size and site. Eight patients died until the date of analysis, 6 died of distant metastasis of melanoma and 2 died of intercurrent diseases. One patient developed local recurrence of the treated tumor and two developed intraocular recurrence outside the irradiated area, the other 69 tumors were still controlled locally on the date of analysis. Seventeen patients developed distant metastasis, 12 in the liver, 4 in the lung, and 1 in the bone. 5 year overall survival, cause-specific survival, and intraocular control rates were 79.7%, 83.1%, and 91.4%, respectively.
Conclusion: C-ion RT can be applied to choroidal melanoma with an acceptable morbidity and sufficient anti-tumor effect, even in the tumors of unfavorable size or site.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NIRS-MD Anderson Symposium on Clinical Issues for Particle Therapy
発表年月日
日付 2008-03-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:30:11.213101
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3