ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Treatment Planning for Carbon Therapy

https://repo.qst.go.jp/records/62478
https://repo.qst.go.jp/records/62478
9b3ba74a-728c-4bac-9946-102b616b2f67
Item type 会議発表用資料 / Presentation(1)
公開日 2008-03-25
タイトル
タイトル Treatment Planning for Carbon Therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 617301

Inaniwa, Taku

Search repository
稲庭 拓

× 稲庭 拓

WEKO 617302

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to use an intensity-controlled raster scan method at the new treatment facility in HIMAC, we have developed a novel code system dedicated to the planning of radiotherapy with the scanned 12C beam. The variation of beam-spread in the direction lateral to the beam axis and non-collinearity of the beam by scanning magnets in the horizontal and vertical directions are considered in the beam model. Inverse planning techniques are implemented in the software in order to obtain the uniform biological dose distribution within the planned target volume (PTV) as well as reduce the dose delivered to the organ at risks (OARs) delineated on clinical CT images. The scan trajectory is determined so that the path length will be minimized by applying a fast simulated annealing algorithm for scan trajectory optimisation. Furthermore, the extra dose inevitably delivered to the irradiated site is integrated into the inverse planning process to shorten the treatment time. The code also copes with the planning for intensity modulated ion therapy (IMIT). Treatment plans were produced for several CT images of the patients treated at HIMAC. The beam steering file is produced with the software in which the position and particle fluence for each raster point is written following the optimised scan trajectory. The reliability of the developed code has been confirmed through the irradiation experiments according to the beam steering file at the secondary beam line in HIMAC.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NIRS-MDA on Clinical Issues for Particle Therapy
発表年月日
日付 2008-03-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:30:19.830195
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3