Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses

https://repo.qst.go.jp/records/62226
https://repo.qst.go.jp/records/62226
899f7c19-1dad-428d-bb5f-380fbe5a41a4
Item type 会議発表用資料 / Presentation(1)
公開日 2007-10-01
タイトル
タイトル Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ko, Susumu

× Ko, Susumu

WEKO 615204

Ko, Susumu

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 615205

Nishizawa, Kanae

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 615206

Akahane, Keiichi

Search repository
Fujii, Keisuke

× Fujii, Keisuke

WEKO 615207

Fujii, Keisuke

Search repository
et.al

× et.al

WEKO 615208

et.al

Search repository
幸 進

× 幸 進

WEKO 615209

en 幸 進

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 615210

en 西澤 かな枝

Search repository
赤羽 恵一

× 赤羽 恵一

WEKO 615211

en 赤羽 恵一

Search repository
藤井 啓輔

× 藤井 啓輔

WEKO 615212

en 藤井 啓輔

Search repository
抄録
内容記述タイプ Abstract
内容記述 X-ray CT apparatuses have been developed as one of very effective diagnostic tools, and been evolved from single to multi-detectors, and single to helical type scanning methods. On the contrary, the doses of patients on X-ray CT examinations are obviously higher than those of general radiographies. In recent, X-ray CT apparatuses have been used for chest examinations of mass-screenings in Japan, and the factors influencing doses of patients are concerns on radiation protection. For estimating the differences by the factors such as beam width and pitch etc. quantitatively, the organ doses of X-ray CT examinations for typical three X-ray CT
apparatuses of different manufactures were directly measured by using thermoluminescence dosimeters and an adult anthropomorphic phantom as the values of normalized organ doses per mAs and effective mAs for the factors. The half-value layers (HVLs) of X-ray CT apparatuses were also measured. The differences of organ doses between the highest and lowest were approximately two times. The organ dose variations among manufactures could be explained by the HVLs as one of the reasons. For the same apparatus, the organ doses were different depending on the factor values (Fig. 1 and 2). The result suggests that the organ doses can be different depending on the kinds of apparatuses even though same X-ray CT examinations would be performed.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Xth EFOMP Congress - Pisa 2007
発表年月日
日付 2007-09-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:33:12.434897
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3