ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Status of Carbon-Ion Therapy Facility and Development for Advanced Treatment

https://repo.qst.go.jp/records/62213
https://repo.qst.go.jp/records/62213
e172ac39-318c-444d-8ff2-2cf294aaf7ab
Item type 会議発表用資料 / Presentation(1)
公開日 2007-09-13
タイトル
タイトル Status of Carbon-Ion Therapy Facility and Development for Advanced Treatment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kitagawa, Atsushi

× Kitagawa, Atsushi

WEKO 615063

Kitagawa, Atsushi

Search repository
北川 敦志

× 北川 敦志

WEKO 615064

en 北川 敦志

Search repository
抄録
内容記述タイプ Abstract
内容記述 1.Heavy-ion radiotherapy has two clear advantages over other types of radiation therapies. One is the localized dose distribution just on a tumor in a human body. It comes from the Bragg peak in the energy deposition and the low multiple scattering of the heavy-ion beam. The other one is the large relative biological effectiveness (RBE) due to the high linear energy transfer. The carbon ion is one of most effective species due to RBE. Over 3000 cancer patients have already been treated with 140-400 MeV/u carbon beams by the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS) since 1994. These clinical results have clearly verified the advantages of carbon ion. Based on our experience at HIMAC, a hospital-specified facility optimized for the carbon-ion therapy has been designed. Its area size and construction cost are almost 1/3 of HIMAC, respectively. The prototype developments of an ECR ion source, a RFQ linac, an IH linac, an acceleration system of synchrotron, a beam-delivery system, and other key-technology parts have been successfully finished. Thus, in co-operation with NIRS, Gunma University has been constructing the carbon-therapy facility since April 2006. There are many other construction plans in the world. In order to improve the present clinical results, it is necessary to create more accurate dose distribution on the tumor without undesired dose deposited on the normal tissue. Beam-scanning methods with respiration-gated irradiation are especially important to treat a cancer located in the trunk of patient. Developments on the new repainting raster-scanning method and so on are now in progress. We will summarize our successful experiences for 13 years, and will report recent developments.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第10回アジア太平洋物理学会議
発表年月日
日付 2007-08-24
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:33:21.466196
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3