ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

New Treatment Facility for Heavy-ion Cancer Therapy at HIMAC

https://repo.qst.go.jp/records/62210
https://repo.qst.go.jp/records/62210
4ca15ae9-1d84-48e9-a462-a9f98e2095ff
Item type 会議発表用資料 / Presentation(1)
公開日 2007-09-13
タイトル
タイトル New Treatment Facility for Heavy-ion Cancer Therapy at HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Noda, Kouji

× Noda, Kouji

WEKO 615047

Noda, Kouji

Search repository
野田 耕司

× 野田 耕司

WEKO 615048

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 The first clinical trial of cancer treatment with carbon beams generated from the HIMAC was conducted in June 1994. The total number of patients treated as of February 2007 was in excess of 3,178. Based on more than ten years of experience with HIMAC, we have proposed a new treatment facility for the purpose of further development of the therapy with HIMAC. This facility, which will be connected with the HIMAC synchrotron, will consist of three treatment rooms: two rooms equipped with horizontal and vertical beam-delivery systems and one room with a rotating gantry. In both the fixed beam-delivery and rotating gantry systems, a 3D beam-scanning method will be employed with gated irradiation with patient respiration in order to increase the treatment accuracy. The energy of the fixed beam-delivery system ranges from 140 to 430 MeV/n. At the present design of the gantry system, the following main specifications are maximum energy of 400 MeV/n, lateral field of 150 mm in square, SOBP size ranging from 40 to 150 mm, and residual range of 250 mm at maximum. Since the beam control for the size, the position and the time structure plays an essential role in the 3D beam scanning with the irradiation gated with patient respiration, the R&D study has been carried out with the HIMAC synchrotron since 2006. We will report the design and R&D studies for the new treatment facility at HIMAC.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第9回欧州加速器応用研究会議(9th European Conference on Accelerators in Applied Research and Technology)
発表年月日
日付 2007-09-07
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:33:23.462542
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3