Wavelet denoising for parametric imaging of the peripheral benzodiazepine receptors with 18F-FEDAA1106

https://repo.qst.go.jp/records/62110
https://repo.qst.go.jp/records/62110
b0d9bdea-26d6-4d6f-9a1f-166d0aea49c1
Item type 会議発表用資料 / Presentation(1)
公開日 2007-05-28
タイトル
タイトル Wavelet denoising for parametric imaging of the peripheral benzodiazepine receptors with 18F-FEDAA1106
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shidahara, Miho

× Shidahara, Miho

WEKO 614258

Shidahara, Miho

Search repository
Ikoma, Youko

× Ikoma, Youko

WEKO 614259

Ikoma, Youko

Search repository
Seki, Chie

× Seki, Chie

WEKO 614260

Seki, Chie

Search repository
et.al

× et.al

WEKO 614261

et.al

Search repository
志田原 美保

× 志田原 美保

WEKO 614262

en 志田原 美保

Search repository
生駒 洋子

× 生駒 洋子

WEKO 614263

en 生駒 洋子

Search repository
関 千江

× 関 千江

WEKO 614264

en 関 千江

Search repository
抄録
内容記述タイプ Abstract
内容記述 Title
WAVELET DENOISING FOR PARAMETRIC IMAGING OF THE PERIPHERAL BENZODIAZEPINE RECEPTORS WITH F-18-FEDAA1106
\nAuthors
Miho Shidahara, Yoko Ikoma, Chie Seki, Yota Fujimura, Hiroshi Ito, Yuichi Kimura, Tetsuya Suhara and Iwao Kanno
\nAffiliations
1 Molecular Imaging Center, National Institute of Radiological Sciences, JAPAN.
\nBackground and aims: The statistical noise of time activity curve (TAC) at voxel level causes severe bias and poor precision for estimated binding potential, BP(=k3/k4), images using a nonlinear least square fitting (NLS). The purpose of this study is to evaluate noise reduction capability of wavelet denoising for estimated BP images of the peripheral benzodiazepine receptor (PBR). 18F-FEDAA1106 is a radioligand for PBR, and its BP images should be formed using NLS because no reference regions can be assumed due to the physiological aspects of PBR1. We applied wavelet denoising to simulate data and clinical dynamic image of PBR with 18F-FEDAA1106.
Methods: After administration of 18F-FEDAA1106, three dimensional dynamic PET scans were performed by ECAT EXACT HR+ system (CTI-Siemens, Knoxville, USA) having 41 frames. The wavelet processing was applied in a volume fashion with a three-dimensional discrete dual-tree complex wavelet transformation2 at 4 scales with 112 subbands. The advantage of wavelet denoising is to realize spatially adaptive smoothing. In order to eliminate noise component in wavelet coefficients, real and imaginary coefficients for each sub-band were individually thresholded with NormalShrink3. Simulations were conducted to evaluate the performance of the wavelet denoising for parameter estimation. A simulated dynamic data was consisted of 4 parts of 2 gray matters (K1=0.25, k2=0.078, k3=0.043 or 0.0516, k4=0.0086), a white matter (K1=0.15, k2=0.075, k3=0.043, k4=0.01), and CSF to simulate anatomical structure of the brain (Hoffman brain phantom: 12812855 pixels, 222 mm). Each part had the BPs of 5, 6, 4.3, and 0, respectively. Then the phantom was smoothed with Gaussian filter (2.5x2.5 mm FWHM) and then Gaussian noise was added to mimic exact measurement at the noise level 20%. The BP images derived from wavelet denoising were compared with true BP image using 156 rectangular ROIs (55 pixel). The Wavelet denoising was also applied to clinical data derived from 3 young normal volunteers. Parametric images of BP were formed using voxel-based NLS fitting, and the results were compared with an ordinary ROI averaged estimates1.
Results: In the simulation studies, estimated BP by denoised image showed better correlation against the true BP values (Fig-1A), although no correlation was observed in the estimates. In clinical data, wavelet denoising improved image quality of the estimates (Fig-1B). Originally estimated BP image includes bias against ROI averaged estimates (Y=1.12X+0.94, R2=0.55), however, estimated BP by denoised image improved relationship with ROI analysis (Y=0.91X+0.95, R2=0.57).
Conclusions: Wavelet denoising improves bias and variation of pharmacokinetic parameters, especially, BP.
\nReference
[1] Fujimura Y, 2006, J Nucl Med, 47, 43-50.
[2] Alpert NM, 2006, NeuroImage, 30, 444-451.
[3] Fourati W, 2005, Inter J on GVIP, 5, 1-9.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Brain'07 and BrainPET'07
発表年月日
日付 2007-05-24
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:34:34.071279
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3