ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Graphite Calorimetry for absdorbed dose measurements in heavy-ion beams

https://repo.qst.go.jp/records/62033
https://repo.qst.go.jp/records/62033
dd82b0e5-d9a1-4bcb-9320-ab29e789c1d0
Item type 会議発表用資料 / Presentation(1)
公開日 2007-03-07
タイトル
タイトル Graphite Calorimetry for absdorbed dose measurements in heavy-ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sakama, Makoto

× Sakama, Makoto

WEKO 613535

Sakama, Makoto

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 613536

Kanai, Tatsuaki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 613537

Fukumura, Akifumi

Search repository
坂間 誠

× 坂間 誠

WEKO 613538

en 坂間 誠

Search repository
金井 達明

× 金井 達明

WEKO 613539

en 金井 達明

Search repository
福村 明史

× 福村 明史

WEKO 613540

en 福村 明史

Search repository
抄録
内容記述タイプ Abstract
内容記述 Graphite calorimetry for absorbed dose measurements in heavy-ion beams
M.Sakama(1)T.Kanai(1.2)A.Fukumura(2)
(1)Tokyo Institute of Technology,Japan(2)National Institute of Radiological Sciences,Japan(m_sakama@nirs.go.jp/Phone:+91-43-251-2111)
\nIn order to sophisticate the radiotherapy,high accuracy knowledge of the absorbed dose delivered to the patient is essential. The main methods of absolute doseimetryare indicated as follows;(a)Doseimetry by ion chamber(b)Fricke dosimetry and (c)Calorimetry. The calorimetry is most direct method of dosemetry due to direct measurement of energy deposit in principle and no requirement of information of radiation fields for the calibration. Many countries tend to adopt the calorimerty to determine the standard absorbed dose to water and become to be capable of deciding the absorbed dose in precision of about 0.6% for photon and electron beams. Despite the recent progress of particle therapy, the parameters such as w-value and stopping power ratio for ionization chambers in the particles is not obtained accurately. Therefore that causes uncertainty in determination of the absolute dose. For this reason, we developed a graphite calorimeter to obtain high precision absobed dose and reduce the uncertainty for various beams. When the absorbed dose of 1 Gy is irradiated to the senseitive volume, the temperature rise is abou 1.4 milliKelvins. The performance require the resolution of plus or minus 7 micro Kelvins to measure it in precision of plus or minus 0.5%. The stability within seberal micro Kelvins per minute is necessary to obtain measureable background.The miniature glass bead thermistors were embedded in the sensitive volume to perform active control of temperature. The resistance change of these themistors is approximately 0.68 Ohms and 488 micro Ohms at temperature rise of 1.4 milliKelvins and 1 micro Kelvins from 20 degrees, respectively. The temperature-measuring themistor is connected to a Wheatstone bridge and the resistance change is measured by lock-in amplifier and nanovoltmeter. Simulations and experiments have been performed for photon and various heavy-ion beams.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Committee on Space Research 36th COSPAR Scientific Assembly 2006
発表年月日
日付 2006-07-23
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:35:28.076281
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3