Dose-rate Effect of High-LET Ion Beams on Human Tumor Cells

https://repo.qst.go.jp/records/61719
https://repo.qst.go.jp/records/61719
10a3eb33-e6e3-44ee-b13f-560d1c9797f1
Item type 会議発表用資料 / Presentation(1)
公開日 2006-08-10
タイトル
タイトル Dose-rate Effect of High-LET Ion Beams on Human Tumor Cells
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 611005

Furusawa, Yoshiya

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 611006

Matsumoto, Yoshitaka

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 611007

Hirayama, Ryoichi

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 611008

Satou, Shinji

Search repository
Satou, Yukio

× Satou, Yukio

WEKO 611009

Satou, Yukio

Search repository
Kanazawa, Mitsutaka

× Kanazawa, Mitsutaka

WEKO 611010

Kanazawa, Mitsutaka

Search repository
Tomitani, Takehiro

× Tomitani, Takehiro

WEKO 611011

Tomitani, Takehiro

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 611012

Ando, Koichi

Search repository
古澤 佳也

× 古澤 佳也

WEKO 611013

en 古澤 佳也

Search repository
松本 孔貴

× 松本 孔貴

WEKO 611014

en 松本 孔貴

Search repository
平山 亮一

× 平山 亮一

WEKO 611015

en 平山 亮一

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 611016

en 佐藤 眞二

Search repository
佐藤 幸夫

× 佐藤 幸夫

WEKO 611017

en 佐藤 幸夫

Search repository
金澤 光隆

× 金澤 光隆

WEKO 611018

en 金澤 光隆

Search repository
富谷 武浩

× 富谷 武浩

WEKO 611019

en 富谷 武浩

Search repository
安藤 興一

× 安藤 興一

WEKO 611020

en 安藤 興一

Search repository
抄録
内容記述タイプ Abstract
内容記述 It is known that radiobiological effectiveness decrease with decrease of the dose-rate for gamma-rays or neutrons. Radiosensitivity as cell survival changes with the dose-rate between 0.2 Gy/hr and 60 Gy/hr (HP Leenhouts et al, J. Radiol. Prot. 10; 95-102, 1990) in mouse CHO cells. There are little reports concerning the dose-arte effects by exposure of ion-beams. Astronauts may receive very low-dose-rate ion-beam radiations. RBE is an important factor to estimate the risk of biological effects by ion-beams, however the RBE is usually estimated from the data at high-dose-rate. Thus, we studied the dose-rate effect on radiosensitivity for heavy ion-beams on cell survival.
A human salivary grand tumor cells (HSG) cultured in Eagle's MEM medium in 5% CO2 conteining air at 37 Co was used. A 290 MeV/u carbon-ion beams having 70keV/um of the LET were used at HIMAC facility in the National Institute of Radiological Sciences, Chiba, Japan. Exponentially growing cells cultured in flasks (NUNC 170920) were irradiated with different doses up to about 4.5 Gy that corresponds the cell survival reduce to be less than 1 %, with different dose-rate between 0.5 and 600 Gy/hr. Irradiated cells were sub-cultured just after the exposure, incubated for 13 days, and then colonies consists more than 50 cells were counted as survived cells.
The data were plotted on a usual semi logarithmic chart, and compare the survival curves with different dose-rate. All the data from different lower dose-rate exposure plotted on a curve produced by high-dose-rate (10 Gy/min) experiments. It is also found that there are no significant changes in survival parameters by the dose-rate. The survival curve parameters, such as alpha, beta, and D0 were 0.86 Gy-1, 0.10 Gy-2, and 0.78 Gy at 10 Gy/min experiments, and the values varied among 0.69-1.11 Gy-1, 0.05-0.15 Gy-2, and 0.74-0.83 Gy, respectively. In conclusion, the dose-rate effect on cell survival could not observe in the dose-rates tested (611-0.49 Gy/hr) on the cells used (HSG). Alternation of the dose-rate may not affect at the estimation of RBE.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 36th COSPAR Scientific Assembly
発表年月日
日付 2006-07-23
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:39:06.558301
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3