ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

The jPET-D4: Imaging Performance of the 4-Layer Depth-of-Interaction PET Scanner

https://repo.qst.go.jp/records/61146
https://repo.qst.go.jp/records/61146
096ab57b-5fa3-4051-b672-5ba068e91d40
Item type 会議発表用資料 / Presentation(1)
公開日 2005-11-01
タイトル
タイトル The jPET-D4: Imaging Performance of the 4-Layer Depth-of-Interaction PET Scanner
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamaya, Taiga

× Yamaya, Taiga

WEKO 605621

Yamaya, Taiga

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 605622

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 The jPET-D4 is a high-performance brain PET scanner which achieves not only high spatial resolution but also high scanner sensitivity by discriminating 4-layer depth-of-interaction (DOI) information. The scanner is designed to have 5 rings of 24 detector blocks each, and the detector block consists of 1,024 GSO crystals of 2.9 mm x 2.9 mm x 7.5 mm, which are arranged in 4 layers of 16 x 16 arrays. At this stage, one of the 5 block-detector rings has been assembled into the jPET-D4 gantry. In this paper, we investigate the imaging performance of the jPET-D4 prototype. In order to reduce computational cost while keeping the advantage of DOI information in iterative image reconstruction, we have proposed the DOI compression (DOIC) method which reduces data dimensions with suppressing resolution loss. We have also proposed an imaging system model optimized for the jPET-D4 which enables fast system matrix calculation while preserving image quality. These methods were applied to the real data of needle sources on a uniform background. The result shows that almost uniform spatial resolution of less than 3 mm is obtained over the field-of-view by using the 4-layer DOI information. The Hoffman 3D brain phantom was also measured to compare the jPET-D4 with the HR+ commercial scanner. The result clearly shows the excellent imaging performance of the jPET-D4. Two or more detector-rings are being assembled, and the first volunteer tests are being planned.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE 2005 Nuclear Science Symposium & Medical Imaging Conference
発表年月日
日付 2005-10-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:45:43.243615
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3