ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Prodution of Short-Pulsed Beam for Ion-Beam Pulse Radiolysis

https://repo.qst.go.jp/records/60619
https://repo.qst.go.jp/records/60619
386548f6-c05b-4810-b5bd-ffdc022349d1
Item type 会議発表用資料 / Presentation(1)
公開日 2004-10-30
タイトル
タイトル Prodution of Short-Pulsed Beam for Ion-Beam Pulse Radiolysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Noda, Kouji

× Noda, Kouji

WEKO 601262

Noda, Kouji

Search repository
野田 耕司

× 野田 耕司

WEKO 601263

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since 1994, the HIMAC (Heavy Ion Medical Accelerator in Chiba) accelerator complex has delivered carbon ions for cancer therapy and other heavy-ions for basic and applied research. One of the objectives of HIMAC is to develop new technologies in heavy-ion therapy and related research. Even in the carbon cancer therapy, it is very important to investigate the behavior of free radicals. For the purpose, the ion-beam pulse radiolysis with the time resolution of microsecond has been carried out at HIMAC. In order to improve the time resolution to nanosecond order, thus, we have studied the production methods of short-pulsed ion-beam. One of the methods is bunch rotation just after momentum cooling through the electron cooling method. In this method, the initial momentum of ion beam in a storage ring is cooled down owing to the strong phase-space compression by the electron cooling, and the beam with the low momentum spread is bunched and rotated by 90 degree in the longitudinal phase-space by applying RF-voltage. We have investigated this method experimentally in the HIMAC synchrotron by using the fully stripped Ar ions with the energy of 6 MeV/u. As a result, it was verified that the pulse length was compressed to less that 100 ns from around 400 ns without the momentum cooling. We will report the experimental result of the method.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 8th European Conference on Accelerator in Applied Research and Thechnology
発表年月日
日付 2004-09-24
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:51:41.703691
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3