ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Measurements of Dose Distributions in Water Using CR-39 for Therapeutic Carbon-Ion Beams

https://repo.qst.go.jp/records/60497
https://repo.qst.go.jp/records/60497
473265b9-faf5-418f-82fa-60e833284c98
Item type 会議発表用資料 / Presentation(1)
公開日 2004-08-03
タイトル
タイトル Measurements of Dose Distributions in Water Using CR-39 for Therapeutic Carbon-Ion Beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 600522

Kohno, Ryosuke

Search repository
河野 良介

× 河野 良介

WEKO 600523

en 河野 良介

Search repository
抄録
内容記述タイプ Abstract
内容記述 It is important for carbon-ion radiotherapy to evaluate biological dose distributions accurately in the body. The biological dose distribution is given by the product of the relative biological effectiveness (RBE) and the physical dose. Here, the RBE is related to linear energy transfer (LET) of charged particle. Therefore, in order to evaluate the biological dose distribution in regions of interest, we have to measure the LET distribution. In this study, we used a CR-39 solid state track detector to measure the LET distribution in water. Therapeutic 12C beam was provided from the Heavy Ion Medical Accelerator in Chiba (HIMAC). For mono-energetic beam of 290 MeV/n, depth-dose distribution deduced from LET distributions using the CR-39 detectors is compared with the measurement by an ionization chamber. The dose distribution by the CR-39 indicated a good agreement with the result by the ionization chamber. On the other hand, as expected, measured dose from the CR-39 have been underestimated in the tail region of Bragg curve, since the CR-39 can not detect low LET particles such as protons from the projectile fragmentation reaction in water. However, effect of these discrepancies on the biological dose distribution is considerably small, because RBE for low LET component is small. We found that it was useful for LET distribution measurements to use the CR-39 detector.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 AAPM 46th Annual Meeting
発表年月日
日付 2004-07-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:53:07.524408
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3