Verification of 11C scanning irradiation with offline PET

https://repo.qst.go.jp/records/60463
https://repo.qst.go.jp/records/60463
cbea6457-3445-43cf-b4e1-6fa29fd4517c
Item type 会議発表用資料 / Presentation(1)
公開日 2004-06-29
タイトル
タイトル Verification of 11C scanning irradiation with offline PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Urakabe, Eriko

× Urakabe, Eriko

WEKO 600358

Urakabe, Eriko

Search repository
et.al

× et.al

WEKO 600359

et.al

Search repository
新谷 恵理子

× 新谷 恵理子

WEKO 600360

en 新谷 恵理子

Search repository
抄録
内容記述タイプ Abstract
内容記述 A scheme for offline PET measurement of 11C beam irradiation field has been developed in order to verify a three-dimensionally conformal irradiation field for particle radiotherapy. With use of positron emitter beams such as 11C, the verification of therapeutic irradiation can be directly accomplished by observing annihilation-pair gamma rays from the stopping point in the patient. One of the features of 11C therapeutic beam is the large number of the annihilation gamma ray observed at the range of the incident beam. The half-life of 11C is 20.39 min, which is appropriate for measurements using offline positron emission tomography (PET).
The experiment to simulate the treatment irradiation and offline PET verification was accomplished with PMMA phantom. The concave-shaped irradiation field was optimised with 1 Gy in uniform phantom. The dose distribution of the concave field is confirmed with multi-channel ionization chamber and the water column in advance. To reduce the set up error at the PET gantry, the platform on the couch of PET is prepared and the reference position of the platform is fixed using the 22Na point source. After the irradiation with 11C (345 MeV/n) by HIMAC scanning system, the phantom is set on the platform in the PET gantry and measured for an hour.
In this conference, the results of the PET verification of 11C irradiation field will be presented.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 40th PTCOG
発表年月日
日付 2004-06-18
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:53:29.330224
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3