ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

重イオンがん治療用小型ECRイオン源の開発

https://repo.qst.go.jp/records/59938
https://repo.qst.go.jp/records/59938
721af4c8-88ed-4fe8-b064-e4cf8c8aa8f3
Item type 会議発表用資料 / Presentation(1)
公開日 2003-09-05
タイトル
タイトル 重イオンがん治療用小型ECRイオン源の開発
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 村松, 正幸

× 村松, 正幸

WEKO 596183

村松, 正幸

Search repository
村松 正幸

× 村松 正幸

WEKO 596184

en 村松 正幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 High-energy heavy-ion cancer treatment is being carried out at Heavy Ion Medical Accelerator in Chiba (HIMAC) with 140-400 MeV/u carbon ions. Ion sources for the medical facilities should have characteristics of easy maintenance, low electric power, good stability and long operation time without maintenance (one year or more). The 10 GHz compact ECRIS with all permanent magnets is developed since 2000. The beam intensity and stability for C4+ are 300 eA and better than 6% during 20 hours with no adjustment of any source parameter. These results are acceptable for the medical requirement.
\nIn addition, in order to realize various applications, beam intensities of the highly charged ions such as oxygen and argon were increased by the following improvements; 1) biased disk method, 2) additional vacuum pomp at the injection side, 3) gas mixing method, 4) biased cylinder. Output currents of O6+ and Ar8+ are more than 120 eA and 140 eA, respectively.
\nRecently, many plans were developed for the construction of the next generation treatment facility. For such facility we have designed a new all permanent magnet ECRIS. Higher magnetic field is chosen than the previous one for increasing beam intensity. The maximum mirror magnetic field on the beam axis are 0.58 T at the extraction side and 0.87 T at the gas injection side. The minimum B strength is 0.25 T. The source is 30 cm diameter and 29 cm in length. Details of the design are reported.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第64回応用物理学会学術講演会
発表年月日
日付 2003-09-02
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:59:21.406537
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3