ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Intercomparison of Radiobiological RBE Among Japanese Proton Therapy Facilities

https://repo.qst.go.jp/records/59919
https://repo.qst.go.jp/records/59919
af532f97-c123-431f-8a87-653c102460b1
Item type 会議発表用資料 / Presentation(1)
公開日 2003-08-27
タイトル
タイトル Intercomparison of Radiobiological RBE Among Japanese Proton Therapy Facilities
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 596009

Furusawa, Yoshiya

Search repository
Aoki, Mizuho

× Aoki, Mizuho

WEKO 596010

Aoki, Mizuho

Search repository
Shino, Yayoi

× Shino, Yayoi

WEKO 596011

Shino, Yayoi

Search repository
Lee, Ryonfa

× Lee, Ryonfa

WEKO 596012

Lee, Ryonfa

Search repository
Zhou, Guangming

× Zhou, Guangming

WEKO 596013

Zhou, Guangming

Search repository
Takai, Nobuhiko

× Takai, Nobuhiko

WEKO 596014

Takai, Nobuhiko

Search repository
Monobe, Manami

× Monobe, Manami

WEKO 596015

Monobe, Manami

Search repository
Fukawa, Takeshi

× Fukawa, Takeshi

WEKO 596016

Fukawa, Takeshi

Search repository
Miyato, Yasuyuki

× Miyato, Yasuyuki

WEKO 596017

Miyato, Yasuyuki

Search repository
Kagiya, Gou

× Kagiya, Gou

WEKO 596018

Kagiya, Gou

Search repository
古澤 佳也

× 古澤 佳也

WEKO 596019

en 古澤 佳也

Search repository
青木 瑞穂

× 青木 瑞穂

WEKO 596020

en 青木 瑞穂

Search repository
志野 弥生

× 志野 弥生

WEKO 596021

en 志野 弥生

Search repository
周 光明

× 周 光明

WEKO 596022

en 周 光明

Search repository
高井 伸彦

× 高井 伸彦

WEKO 596023

en 高井 伸彦

Search repository
物部 真奈美

× 物部 真奈美

WEKO 596024

en 物部 真奈美

Search repository
扶川 武志

× 扶川 武志

WEKO 596025

en 扶川 武志

Search repository
宮戸 靖幸

× 宮戸 靖幸

WEKO 596026

en 宮戸 靖幸

Search repository
鍵谷 豪

× 鍵谷 豪

WEKO 596027

en 鍵谷 豪

Search repository
抄録
内容記述タイプ Abstract
内容記述 INTRODUCTION
HIMAC (Heavy-ion Medical Accelerator in Chiba) has constructed in 1993, and clinical trials has started in 1994 together with academic research activities, including physics, engineering, and biology. Pre-clinical radiobiological studies have performed to estimate clinical RBE for hadron beams. Following the HIMAC, several hadron therapy facilities (HIBMC, Hyogo; NCCHE, Kashiwa; WERC, Tsuruga; PMRC, Tsukuba; SCC, Shizuoka) have started the therapy in Japan. We have evaluated the RBE of each hadron beams for all the facilities with the same biological system and technical staffs as well as at HIMAC.
METHODS
Human salivary gland tumor cells (HSG) were used for the studies. All experiments were performed with single-dose exposures for both proton beams and linac X-rays at each facilities. All 60 mm SOBP beams were generated from 180-190 MeV proton beam, and the energy of high-energy linac X-rays were 4-6 MeV, but it depends on the facilities. Samples were placed at the plateau position or the entrance, middle, or proximal positions of SOBP beam or at the 50 mm depth position of the linac beam. The D10 values from survival curves by the colony formation assay were obtained. The RBE values of proton beams were calculated to X-ray data.
RESULTS
The average RBE at the middle of SOBP beam from all facilities was 1.030+/-0.017 (mean +/- SD). Flatness of the RBE in the SOBP were slightly disposed to increase with the depth. The values were slightly lower at the entrance, and little bit higher at the distal than that at the middle position.
DISCUSSION
X-ray data showed very good agreement and the deviations were less than 2 % among the facilities. The RBE values also showed good agreement among the facilities with 2 % or less standard deviation. Some difficulties were found in the irradiation systems, i.e. the dose determination and/or geometrical sample setting methods are different among the facilities. This may makes difficult exact comparative judgments of the radiobiological data. During the radiobiological experiments process, several problems were found and have solved. In this point of view, preclinical experiments were important as a simulation of patient treatments.
CONCLUSION
The RBE values for all proton therapy facilities in Japan were similar (1.02) with small deviation. The depth-dose distribution of all the SOBP beams has designed very well, and showed good uniformities of biological dose at all facilities. Physical dosimetry system should be unify for all the facilities to compare the results.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 WC2003
発表年月日
日付 2003-08-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:59:34.125476
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3