ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Introduction of Electrochemical Etching Devices in VINCA

https://repo.qst.go.jp/records/59855
https://repo.qst.go.jp/records/59855
115c59fe-e4fb-44f9-bcea-0c2dd2a06442
Item type 会議発表用資料 / Presentation(1)
公開日 2003-07-09
タイトル
タイトル Introduction of Electrochemical Etching Devices in VINCA
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fujimoto, Kenzo

× Fujimoto, Kenzo

WEKO 595607

Fujimoto, Kenzo

Search repository
藤元 憲三

× 藤元 憲三

WEKO 595608

en 藤元 憲三

Search repository
抄録
内容記述タイプ Abstract
内容記述 Relatively high dose to the lung due to radon and its progeny in the normal natural environment was recognized a few decades ago. However, the dose had not been paid much attention since its dose was localized only in the lung. In late seventies radon became worldwide concern due to the introduction of the dose unit of effective dose equivalent (effective dose in present terminology) by ICRP Publ. 26. In the early eighties UNSCEAR requested every member states to carry out nation-wide indoor radon survey for the population dose estimation in the world. Only limited number of countries at that time had completed the nation-wide indoor radon survey, such as Canada. In accordance with the UNSCEAR's request a radon survey was conducted by our group in Japan during 1985 and 1991. A robust, non-expensive and reliable passive detector was searched for the use of our nation-wide survey. Karlsruhe type passive radon detector was then chosen for the survey. The detector film was polycarbonate and its treatment after the exposure was the electrochemical etching. Using this method more than 7,000 houses throughout Japan were measured to obtain annual average indoor radon concentration. The survey demonstrated that the percentage of houses having high radon concentration more than 150 Bq m-3 was only 0.4% of the house stock in Japan. We additionally found Karlsruhe type passive radon detector had higher air exchange rate than expected and showed radon concentrations affected by thoron. To solve the interference of thoron in radon measurement a new passive detector (UFO type) was designed to discriminate radon from thoron. The second nation-wide survey using the UFO type detector was conducted during 1992 and 1996 with a relatively small scale. After the finalization of our indoor radon surveys, all our devices related to the passive radon measurements were donated to Vinca in November 2002 wishing the active usage of the tools in this region.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Promotion of New Electrochemical Etching Facility and Its Applications to Natural Radiation Studies in Western Balkan Countries
発表年月日
日付 2003-07-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:00:16.200209
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3