ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Measurement of Variation in Water Equivalent Path Length

https://repo.qst.go.jp/records/59510
https://repo.qst.go.jp/records/59510
79b93cc1-cf55-4a3d-b2bc-6e3db1a75977
Item type 会議発表用資料 / Presentation(1)
公開日 2002-12-26
タイトル
タイトル Measurement of Variation in Water Equivalent Path Length
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Minohara, Shinichi

× Minohara, Shinichi

WEKO 592378

Minohara, Shinichi

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 592379

Kanai, Tatsuaki

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 592380

Endo, Masahiro

Search repository
Katou, Hirotoshi

× Katou, Hirotoshi

WEKO 592381

Katou, Hirotoshi

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 592382

Miyamoto, Tadaaki

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 592383

Tsujii, Hirohiko

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 592384

en 蓑原 伸一

Search repository
金井 達明

× 金井 達明

WEKO 592385

en 金井 達明

Search repository
遠藤 真広

× 遠藤 真広

WEKO 592386

en 遠藤 真広

Search repository
加藤 博敏

× 加藤 博敏

WEKO 592387

en 加藤 博敏

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 592388

en 宮本 忠昭

Search repository
辻井 博彦

× 辻井 博彦

WEKO 592389

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To propose a method for estimating uncertainties of the range calculation in particle radiotherapy associated with organ motion along with patient respiration.
Methods and Materials: A set of sequential CT images every 0.2 seconds was reconstructed from continuous x ray projection data accumulated by the dynamic scanning mode in helical CT scanner. At the same time of CT data acquisition, respiratory signal of patient and on off signal of x ray on CT scanner were recorded. From these data, the timing of each CT image was related with the phase of respiration waveform. These CT images were analyzed in our treatment planning system that included the function converting from CT number to water equivalent path lengt(WEL). A set of CT images of the patient with liver cancer at upper right lobe was analyzed. The geometrical sizes of the liver and WELs from body surface to iso center were measured in each CT image. Results: WEL variations of depth from body surface to iso center were 6.2mm and 18.9mm at anterior posterior and posterior anterior direction, respectively. Liver size was changed to 35.2mm. However these variations were shown to be considerably reduced by gated irradiation.
Conclusion: The proposed method using sequential CT images with respiration waveform was shown to be useful to evaluate the uncertainties of the range calculation associated with patient breathing. The variation of the depth along the beam path was presented in WEL rather than geometrical length.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 3rd Korea-Japan joint meeting on medical physics
発表年月日
日付 2002-09-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:04:06.733594
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3