{"_buckets": {"deposit": "86e9a020-7ebd-4e7b-915c-2e747a843a18"}, "_deposit": {"created_by": 1, "id": "58779", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "58779"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00058779", "sets": ["11"]}, "author_link": ["586309", "586330", "586334", "586313", "586307", "586306", "586317", "586325", "586320", "586304", "586332", "586321", "586326", "586329", "586323", "586303", "586318", "586312", "586336", "586308", "586302", "586319", "586333", "586322", "586316", "586335", "586328", "586311", "586310", "586324", "586300", "586327", "586331", "586314", "586315", "586301", "586305"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "65", "bibliographicPageStart": "58", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "日本加速器学会誌"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A superconducting rotating-gantry for carbon-ion radiotherapy was developed. This isocentric gantry can transport carbon ions having kinetic energies of between E=430-56 MeV/u to an isocenter over an irradiation angle of ±180 degrees, and is further capable of performing three-dimensional raster-scanning irradiation. The rotating gantry equips combined-function superconducting magnets. Since these magnets can provide both dipole and quadrupole fields, no quadrupole magnet is required for beam focusing. Having used the combined-function superconducting magnets and optimized the layout of the gantry as well as the beam optics, the length and radius of the gantry became approximately 13 m and 5.5 m, respectively, which are comparable to those for proton gantries. Construction of the entire rotating-gantry system was completed by the end of September, 2015. Having performed beam commissioning over various combinations of gantry angles and beam energies, we could successfully obtain the designed beam quality, which satisfies the requirements of scanning irradiation. Cancer treatments using the superconducting rotating-gantry were started since May, 2017.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩田, 佳之"}], "nameIdentifiers": [{"nameIdentifier": "586300", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "586301", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井, 敏之"}], "nameIdentifiers": [{"nameIdentifier": "586302", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上, 健"}], "nameIdentifiers": [{"nameIdentifier": "586303", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤田, 敬"}], "nameIdentifiers": [{"nameIdentifier": "586304", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 眞二"}], "nameIdentifiers": [{"nameIdentifier": "586305", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 慎一郎"}], "nameIdentifiers": [{"nameIdentifier": "586306", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川, 卓司"}], "nameIdentifiers": [{"nameIdentifier": "586307", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "原, 洋介"}], "nameIdentifiers": [{"nameIdentifier": "586308", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水島, 康太"}], "nameIdentifiers": [{"nameIdentifier": "586309", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "早乙女, 直也"}], "nameIdentifiers": [{"nameIdentifier": "586310", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丹正, 亮平"}], "nameIdentifiers": [{"nameIdentifier": "586311", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "皿谷, 有一"}], "nameIdentifiers": [{"nameIdentifier": "586312", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松葉, 俊哉"}], "nameIdentifiers": [{"nameIdentifier": "586313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本, 哲也"}], "nameIdentifiers": [{"nameIdentifier": "586314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "新井, 弘樹"}], "nameIdentifiers": [{"nameIdentifier": "586315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "荻津, 透"}], "nameIdentifiers": [{"nameIdentifier": "586316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "尾花, 哲浩"}], "nameIdentifiers": [{"nameIdentifier": "586317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "雨宮, 尚之"}], "nameIdentifiers": [{"nameIdentifier": "586318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "折笠, 朝文"}], "nameIdentifiers": [{"nameIdentifier": "586319", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高山, 茂貴"}], "nameIdentifiers": [{"nameIdentifier": "586320", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩田 佳之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586321", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586322", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井 敏之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586323", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586324", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤田 敬", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 眞二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586328", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "原 洋介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586329", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水島 康太", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586330", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "早乙女 直也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586331", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丹正 亮平", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586332", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "皿谷 有一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586333", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松葉 俊哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586334", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "荻津 透", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586335", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "雨宮 尚之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "586336", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "炭素線治療用超伝導回転ガントリーの研究開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "炭素線治療用超伝導回転ガントリーの研究開発"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/58779", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-09-28"}, "publish_date": "2017-09-28", "publish_status": "0", "recid": "58779", "relation": {}, "relation_version_is_last": true, "title": ["炭素線治療用超伝導回転ガントリーの研究開発"], "weko_shared_id": -1}
炭素線治療用超伝導回転ガントリーの研究開発
https://repo.qst.go.jp/records/58779
https://repo.qst.go.jp/records/5877939bf9714-6a9e-475f-9797-0885e5bdb4c4
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-09-28 | |||||
タイトル | ||||||
タイトル | 炭素線治療用超伝導回転ガントリーの研究開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岩田, 佳之
× 岩田, 佳之× 野田, 耕司× 白井, 敏之× 村上, 健× 藤田, 敬× 佐藤, 眞二× 森, 慎一郎× 古川, 卓司× 原, 洋介× 水島, 康太× 早乙女, 直也× 丹正, 亮平× 皿谷, 有一× 松葉, 俊哉× 藤本, 哲也× 新井, 弘樹× 荻津, 透× 尾花, 哲浩× 雨宮, 尚之× 折笠, 朝文× 高山, 茂貴× 岩田 佳之× 野田 耕司× 白井 敏之× 村上 健× 藤田 敬× 佐藤 眞二× 森 慎一郎× 古川 卓司× 原 洋介× 水島 康太× 早乙女 直也× 丹正 亮平× 皿谷 有一× 松葉 俊哉× 荻津 透× 雨宮 尚之 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A superconducting rotating-gantry for carbon-ion radiotherapy was developed. This isocentric gantry can transport carbon ions having kinetic energies of between E=430-56 MeV/u to an isocenter over an irradiation angle of ±180 degrees, and is further capable of performing three-dimensional raster-scanning irradiation. The rotating gantry equips combined-function superconducting magnets. Since these magnets can provide both dipole and quadrupole fields, no quadrupole magnet is required for beam focusing. Having used the combined-function superconducting magnets and optimized the layout of the gantry as well as the beam optics, the length and radius of the gantry became approximately 13 m and 5.5 m, respectively, which are comparable to those for proton gantries. Construction of the entire rotating-gantry system was completed by the end of September, 2015. Having performed beam commissioning over various combinations of gantry angles and beam energies, we could successfully obtain the designed beam quality, which satisfies the requirements of scanning irradiation. Cancer treatments using the superconducting rotating-gantry were started since May, 2017. | |||||
書誌情報 |
日本加速器学会誌 巻 14, 号 2, p. 58-65, 発行日 2017-07 |