ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. その他誌上発表

Quantification of Neuroreceptors and Neurotransporters

https://repo.qst.go.jp/records/58123
https://repo.qst.go.jp/records/58123
f8009a7a-e580-472d-8121-1f9c28f942fa
Item type 一般雑誌記事 / Article(1)
公開日 2012-07-31
タイトル
タイトル Quantification of Neuroreceptors and Neurotransporters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ito, Hiroshi

× Ito, Hiroshi

WEKO 583274

Ito, Hiroshi

Search repository
Naganawa, Mika

× Naganawa, Mika

WEKO 583275

Naganawa, Mika

Search repository
Seki, Chie

× Seki, Chie

WEKO 583276

Seki, Chie

Search repository
Takano, Harumasa

× Takano, Harumasa

WEKO 583277

Takano, Harumasa

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 583278

Kanno, Iwao

Search repository
Suhara, Tetsuya

× Suhara, Tetsuya

WEKO 583279

Suhara, Tetsuya

Search repository
伊藤 浩

× 伊藤 浩

WEKO 583280

en 伊藤 浩

Search repository
長縄 美香

× 長縄 美香

WEKO 583281

en 長縄 美香

Search repository
関 千江

× 関 千江

WEKO 583282

en 関 千江

Search repository
高野 晴成

× 高野 晴成

WEKO 583283

en 高野 晴成

Search repository
菅野 巖

× 菅野 巖

WEKO 583284

en 菅野 巖

Search repository
須原 哲也

× 須原 哲也

WEKO 583285

en 須原 哲也

Search repository
抄録
内容記述タイプ Abstract
内容記述 The binding potential relative to the concentration of nondisplaceable radiotracer in brain (BPND), corresponding to the ratio of the density of neuroreceptors or neurotransporters available to bind radiotracer in vivo (Bavail) to the dissociation constant of the radiotracer (KD), can be measured by positron
emission tomography (PET) with various radiotracers. PET measures the total radioactivity in brainregions, and therefore the differentiation of specific binding from the background of nondisplaceable binding is a fundamental problem in quantitative analyses of PET data. A true equilibrium condition can be obtained only by continuous intravenous infusion of radiotracer. Equilibrium condition after bolus injection of radiotracer can practically be defined as peak equilibrium at the transient moment when the specific binding is maximal. For equilibrium condition, BPND is expressed as the ratio of radiotracer concentration of specific binding to nondisplaceable binding estimated using a reference region. Kinetic analysis, which is based on the assumption that radiotracer binding can be described by the standard twotissue compartment model, allows the differentiation of the specific binding from the background of nondisplaceable binding, therefore revealing BPND. For radiotracers with no ideal reference region, BPND can be calculated only by kinetic analysis. Distribution volumes can also be estimated by several graphic plot analyses, as well as by kinetic analysis. Graphic plot analyses can be used to distinguish graphically whether radiotracers show reversible or irreversible binding. A graphic plot analysis recently developed can also be used to distinguish graphically whether the radiotracer binding includes specific binding or not. To avoid the measurement of arterial input function, several quantitative approaches based on the use of a reference region have been developed. Both the simplified reference tissue model and multilinear reference tissue model methods were widely used to calculate BPND without the arterial input function. For each radiotracer and each purpose of PET study, an adequate quantification method should be employed.
書誌情報 Neuromethods

巻 71, p. 149-161, 発行日 2012-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0893-2336
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:19:31.770515
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3