ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. その他誌上発表

REMPAN Response to Fukushima - Biodosimetry for workers at Fukushima Nuclear Power Station

https://repo.qst.go.jp/records/57998
https://repo.qst.go.jp/records/57998
b758bfca-74f5-4b6d-b288-68e22cf7c16c
Item type 一般雑誌記事 / Article(1)
公開日 2011-12-12
タイトル
タイトル REMPAN Response to Fukushima - Biodosimetry for workers at Fukushima Nuclear Power Station
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Suto, Yumiko

× Suto, Yumiko

WEKO 582763

Suto, Yumiko

Search repository
Akashi, Makoto

× Akashi, Makoto

WEKO 582764

Akashi, Makoto

Search repository
數藤 由美子

× 數藤 由美子

WEKO 582765

en 數藤 由美子

Search repository
明石 真言

× 明石 真言

WEKO 582766

en 明石 真言

Search repository
抄録
内容記述タイプ Abstract
内容記述 The National Institute of Radiological Sciences (NIRS) is the national center for radiation emergency medical preparedness in the nuclear disaster prevention system of Japan. Since the Fukushima Nuclear Power Station accident on March 11, 2011, NIRS has received many requests by e-mail and phone from colleagues throughout the world including those of WHO BioDoseNet.
Currently three staff members of the Research Center for Radiation Emergency Medicine have been on standby for biodosimetry of workers at the accident site with storage of as many as 1,000 Dicentric Analysis tests and two sets of AXIO Imager.Z2 (Carl Zeiss, Inc.) equipped with a CCD camera and Metafer 4 (MetaSystems GmbH), one of which has been lent gratuitously by courtesy of these companies.
In principle, following the IAEA Technical Reports Series No. 405 "Cytogenetic Analysis for Radiation Dose Assessment", Vienna, 2001 (http://www-pub.iaea.org/MTCD/publications/PDF/TRS405_scr.pdf), we perform cell culture, and accomplish a triage-scoring on the day of cell fixation and dose estimation with our calibration curve using a Cs-137 source within a day or two. When necessary, members of the Japan Chromosome Network consisting of nine laboratories will be asked for assistance.
For three months, we received nine blood samples from workers for Dicentric Analysis. Fortunately their doses of external exposure were relatively low, and thus we scored 100 cells / donor for triage and 1,000 cells / donor for dose estimation.
In this instance we have simultaneously faced a nuclear disaster and large earthquakes covering a wide area of our country; the transportation system was paralyzed and the supply of electricity was stopped for a while. Moreover, laboratories and suppliers (machines, reagents, and buildings) were damaged in Tohoku district; some staff members of our center became refugees in the first few days after the earthquakes.
As a lesson learned, in future a much better backup system should be established in Japan to prepare for the worst scenario. Lastly we are very thankful for the offers of help extended to us so far.
書誌情報 REMPAN e-Newsletter (Online Only : URL:http://rempan.uk-wuerzburg.de/en/downloads.html)

号 3, p. 2-2, 発行日 2011-07
出版者
出版者 WHO
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:20:54.520830
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3