ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. その他誌上発表

Tracer Conversion Rate and Accuracy of Compartmental Model Parameter in Irreversibly Trapped Radiotracer Method

https://repo.qst.go.jp/records/57071
https://repo.qst.go.jp/records/57071
9804e5ae-a9d5-4f28-8a9d-b433eeb24a94
Item type 一般雑誌記事 / Article(1)
公開日 2006-07-06
タイトル
タイトル Tracer Conversion Rate and Accuracy of Compartmental Model Parameter in Irreversibly Trapped Radiotracer Method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nagatsuka, Shin-ichiro

× Nagatsuka, Shin-ichiro

WEKO 578318

Nagatsuka, Shin-ichiro

Search repository
Fukushi, Kiyoshi

× Fukushi, Kiyoshi

WEKO 578319

Fukushi, Kiyoshi

Search repository
Namba, Hiroki

× Namba, Hiroki

WEKO 578320

Namba, Hiroki

Search repository
Shinotoh, Hitoshi

× Shinotoh, Hitoshi

WEKO 578321

Shinotoh, Hitoshi

Search repository
Tanaka, Noriko

× Tanaka, Noriko

WEKO 578322

Tanaka, Noriko

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 578323

Tanada, Shuji

Search repository
Irie, Toshiaki

× Irie, Toshiaki

WEKO 578324

Irie, Toshiaki

Search repository
長塚 伸一郎

× 長塚 伸一郎

WEKO 578325

en 長塚 伸一郎

Search repository
福士 清

× 福士 清

WEKO 578326

en 福士 清

Search repository
難波 宏樹

× 難波 宏樹

WEKO 578327

en 難波 宏樹

Search repository
篠遠 仁

× 篠遠 仁

WEKO 578328

en 篠遠 仁

Search repository
田中 典子

× 田中 典子

WEKO 578329

en 田中 典子

Search repository
棚田 修二

× 棚田 修二

WEKO 578330

en 棚田 修二

Search repository
入江 俊章

× 入江 俊章

WEKO 578331

en 入江 俊章

Search repository
抄録
内容記述タイプ Abstract
内容記述 Blood flow linitation of tracer delivery to tissues often affects accuracy and precision of kinetic parameter estimates, particularly in the K3 parameter (tracer conversion rate) of irreverisible tracers in tissues with high K3. As an example of such irreversible radiotracers,[11C] N-methylpiperidinyl-4-acetate, which is metabolically trapped in the brain, was used in the present study. The extent of PET data error in the scanning conditions employed was estimated by analyzing relationships in radioactivity count, standard error of pixel data, and observed PET data error in regiouns of inerest taken in emission images of a homogenous phantom and healthy human subjects. In several cerebral regions with different K3, standard time-radioactivity curves were obtained from one particular subject using three-compartment kinetic model analysis with nonlinear leaast-squares method.The standard time-radioactivity curve and the estimated PET data error were used to generate 100 different time-radioactivity data sets in each region. Two analytical methods for kinetic parameter estimation, i,e., conventional nonlinear least-squares method and shape analysis that estimtes K3 without using input function, were then applied to the sinulated data sets to evaluate the accuracy and precicion of K3 estimates. Both methods gave higher accuracy and precision of K3 in regions with lower K3. The dynamic range of K3 estimation was slightly Wider in the nonlinear least-squares method than in the shape analysis.
書誌情報 Physiological Imaging of the Brain with PET

p. 139-144, 発行日 2001
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:31:13.553746
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3