Additional Calibration of the Radiation Assessment Detector (RAD) Using 1H and 2H Beams at the NIRS Cyclotron

https://repo.qst.go.jp/records/55969
https://repo.qst.go.jp/records/55969
794cd991-7266-47eb-85c4-506dc9177893
Item type 一般雑誌記事 / Article(1)
公開日 2015-12-22
タイトル
タイトル Additional Calibration of the Radiation Assessment Detector (RAD) Using 1H and 2H Beams at the NIRS Cyclotron
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 C.Zeitlin

× C.Zeitlin

WEKO 572700

C.Zeitlin

Search repository
Weigle, G.

× Weigle, G.

WEKO 572701

Weigle, G.

Search repository
Y.Tyler

× Y.Tyler

WEKO 572702

Y.Tyler

Search repository
D.Hassler

× D.Hassler

WEKO 572703

D.Hassler

Search repository
B.Ehresmann

× B.Ehresmann

WEKO 572704

B.Ehresmann

Search repository
H.Kitamura

× H.Kitamura

WEKO 572705

H.Kitamura

Search repository
Zeitlin Cary

× Zeitlin Cary

WEKO 572706

en Zeitlin Cary

Search repository
Weigle Gerald

× Weigle Gerald

WEKO 572707

en Weigle Gerald

Search repository
Tyler Yvette

× Tyler Yvette

WEKO 572708

en Tyler Yvette

Search repository
Hassler Donald

× Hassler Donald

WEKO 572709

en Hassler Donald

Search repository
Ehresmann Bent

× Ehresmann Bent

WEKO 572710

en Ehresmann Bent

Search repository
北村 尚

× 北村 尚

WEKO 572711

en 北村 尚

Search repository
抄録
内容記述タイプ Abstract
内容記述 In June 2014, we performed an experiment at the NIRS Cyclotron to help us better understand the calibration of the flight spaceunit of the Radiation Assessment Detector (RAD). The flight unit is aboard the Curiosity rover on Mars. The flight apare has previously been extensively calibrated in the P2 course at HIMAC with high-energy heavy ion beams, but one of the interesting observations-first during the flight to Mars and later on the surface-has been the relatively large fluxes of deuterons and tritons. It is important to be sure we are measuring these particles with the correct energy scale, which is non-trivial due to the fact that the energies are mostly measured in the RAD "D" detector, a CsI(Tl) scintillator in which quenching of the light output may be an importantfactor.
書誌情報 平成26年度 サイクロトロン利用報告書

p. 66-68, 発行日 2015-11
関連サイト
識別子タイプ URI
関連識別子 http://web.nirs.go.jp/HomePage/Jyuryushi/cyc/sr/sr_26.pdf
関連名称 http://web.nirs.go.jp/HomePage/Jyuryushi/cyc/sr/sr_26.pdf
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:43:17.531159
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3