ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 研究・技術・調査報告

晩期障害マウスモデルを用いた重粒子線治療有害事象の検討

https://repo.qst.go.jp/records/55619
https://repo.qst.go.jp/records/55619
c9d7b078-4b53-4d3f-8a37-0cc07cff732e
Item type 一般雑誌記事 / Article(1)
公開日 2008-10-03
タイトル
タイトル 晩期障害マウスモデルを用いた重粒子線治療有害事象の検討
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 柳澤, 充

× 柳澤, 充

WEKO 569066

柳澤, 充

Search repository
盛武, 敬

× 盛武, 敬

WEKO 569067

盛武, 敬

Search repository
中渡, 美也子

× 中渡, 美也子

WEKO 569068

中渡, 美也子

Search repository
今留, 香織

× 今留, 香織

WEKO 569069

今留, 香織

Search repository
酒井, 美奈子

× 酒井, 美奈子

WEKO 569070

酒井, 美奈子

Search repository
中村, 悦子

× 中村, 悦子

WEKO 569071

中村, 悦子

Search repository
岩川, 眞由美

× 岩川, 眞由美

WEKO 569072

岩川, 眞由美

Search repository
今井, 高志

× 今井, 高志

WEKO 569073

今井, 高志

Search repository
柳澤 充

× 柳澤 充

WEKO 569074

en 柳澤 充

Search repository
盛武 敬

× 盛武 敬

WEKO 569075

en 盛武 敬

Search repository
中渡 美也子

× 中渡 美也子

WEKO 569076

en 中渡 美也子

Search repository
今留 香織

× 今留 香織

WEKO 569077

en 今留 香織

Search repository
酒井 美奈子

× 酒井 美奈子

WEKO 569078

en 酒井 美奈子

Search repository
中村 悦子

× 中村 悦子

WEKO 569079

en 中村 悦子

Search repository
岩川 眞由美

× 岩川 眞由美

WEKO 569080

en 岩川 眞由美

Search repository
今井 高志

× 今井 高志

WEKO 569081

en 今井 高志

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose---To clarify the molecular mechanism of radiation induced late injury in normal tissue, using murine model. In the first year of this study, aiming to irradiate the lung or the urinary bladder of mice with carbon-ion, new type of collimators was constructed.
Materials and methods --- C3H/HeNrs and C57BL/6J, 8-week-old female mice were used through experiments. The position of the target, either lung or bladder, was confirmed by x-ray photographs. Also, the absorbed dose at the target was confirmed using photoluminescence dosimeter (PLD) and ionization chamber. Exposures were conducted using horizontal carbon-12 beams with 290 MeV/u at a dose rate of approximately 3 Gy/min within the 6-cm spread-out bragg peak (SOBP). Gamma-rays were used as reference beam with new collimators. To evaluate the effects of C-ion irradiation on lungs, pathological changes and immunohistochemical stainings for CD44 and Bak at 6 hr, day16, 28 and 56 after thoracic irradiation were analyzed. To evaluate the adverse effects on the bladder,cystometry and pathological evaluation were performed.The total RNA was extracted from irradiated tissues, which were removed on day1,4,8,15,29,60,90,150,240 and 360 after irradiation for microarray analysis to elucidate the molecular response to irradiation.
Results --- The number of CD44 and Bak positive cells in the irradiated lungs were changed after irradiation. The capacity of the urinary bladder and the compliance were decreased significantly at day1,4,8 and 29 after irradiation.
書誌情報 放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書

巻 NIRS-M-214, 号 HAIMAC-129, p. 51-52, 発行日 2008-06
出版者
出版者 放医研
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:47:23.055669
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3